NO SURPRICES FOR YOUR PATIENTS

non contact tonometer tomey - us ophthalmic
Air Noise Like a Gentle Whisper

The sound of air being released from the equipment can sometimes startle patients. The FT-1000 has an air noise level of only 55 dB—gentle as a whisper—ensuring that patients remain comfortable during the examination.

non contact tonometer tomey - us ophthalmic
Notifying Patients of the Measurement Timing

Before measurement begins, the FT-1000's measuring head moves back and forth to alert the patient. This helps eliminate the surprise of a sudden puff of air, allowing patients to stay relaxed throughout the exam.

ENSURES EASY EXAMINATIONS FOR PATIENTS

Touch Alignment Enables Swift Measurement

"Please open your eyes wide." "Please don’t move." We aim to minimize patient discomfort as much as possible. With the FT-1000’s Touch Alignment feature, simply touching the displayed eye on the screen aligns the eye center with the center of the screen. The Auto Alignment and Auto Shot functions then initiate measurement immediately.
This is another major benefit for patient care.

non contact tonometer tomey - us ophthalmic

A simple touch on the pupil center shown on the screen roughly aligns the eye’s position with the center of the display.

non contact tonometer tomey - us ophthalmic

Lightly press the center of the screen to move the measuring head toward the patient. The Auto Alignment and Auto Shot functions will then quickly complete the measurement.

Measurement Time Lag of Only 15 ms

The FT-1000 minimizes the delay between alignment and measurement to approximately 15 milliseconds. This advancement reduces measurement errors caused by blinking or slight eye movement, sparing patients from repeated exams. The system is designed to minimize the number of air puffs needed—enhancing patient comfort.

non contact tonometer tomey - us ophthalmic
Quick Charge

When holding a patient’s eyelid during consecutive measurements, speed is essential. The FT-1000’s quick-charge circuit eliminates downtime between measurements, allowing smooth, continuous operation. This reduces the time patients need to keep their eyes open—another comfort-focused innovation.

non contact tonometer tomey - us ophthalmic
Chin Rest Height Indicator

The chin rest height is displayed on the LCD monitor, allowing you to adjust it before the patient positions their face. This avoids the need for the patient to move their head up and down while pressing against the forehead pad—a thoughtful touch, especially appreciated by patients wearing makeup.

non contact tonometer tomey - us ophthalmic
Large Measuring Head Stroke

The FT-1000 features a vertical measuring head stroke of 45 mm. This extended range significantly reduces the need to adjust the chin rest and shortens overall examination time.

CONSIDERING PATIENT SAFETY

non contact tonometer tomey - us ophthalmic
Reliable Touch Sensor

Even if the measuring nozzle comes into contact with the patient, the touch sensor is immediately activated to stop the measuring head. This feature allows patients to feel more relaxed during examinations.

non contact tonometer tomey - us ophthalmic
Digitally Adjustable Limiter for Each Patient

The limiter prevents the measuring head from moving too close to the patient's eyes. The FT-1000 uses digital control to finely adjust the optimal limiter position for each individual. It incorporates four safety mechanisms:
  • An alarm
  • A warning screen when the measuring head is too close to the eye
  • A limiter to maintain a safe distance
  • A touch sensor that stops movement upon contact

CONSISTENT MEASURING ACCURACY

non contact tonometer tomey - us ophthalmic
Constant Air Pressure Ensured

Non-contact tonometry involves converting applanation air pressure into intraocular pressure. We believe that maintaining consistent conditions for every measurement is critical for accuracy. The FT-1000 includes a dedicated control system that stabilizes air pressure, ensuring consistent measurement results.

non contact tonometer tomey - us ophthalmic
Values Displayed in "hPa" or "mmHg"

Users can select either "mmHg" or "hPa" as the unit for intraocular pressure. Even if clinical standards change in the future, the FT-1000 remains fully compatible.

MAKING EXAMINATION EASIER

non contact tonometer tomey - us ophthalmic
Large Color Display and Icons

Thanks to the 5.7-inch color TFT LCD and easy-to-understand icons, even new users can operate the FT-1000 with ease.

non contact tonometer tomey - us ophthalmic
Comfortable Operation and Intraocular Pressure Correction from the Touch Panel

Deleting unnecessary measurements, such as error data, can sometimes be troublesome. However, the FT-1000 allows you to easily delete this data from the touch panel. Additionally, the FT-1000 features a function for correcting intraocular pressure. This can be done simply by entering the measured central corneal thickness of the examined eye.

EASING MAINTENANCE

non contact tonometer tomey - us ophthalmic
Drop-in Printer Paper Is Simple

Replacing printer paper is easy: just drop in a new paper roll and close the cover. There is no need to thread or feed the paper manually.

non contact tonometer tomey - us ophthalmic
The Nozzle Is Easy to Clean

Cleaning the nozzle is simple—just wipe it with a cloth dampened with alcohol. In addition, the critical optical components are located 32 mm behind the nozzle, making it unlikely for these internal parts to become dirty.

Measuring Intraocular Pressure
Measurable Range 0 to 60 mmHg (0 to 80hPa)
Measuring Unit mmHg / hPa
Observation Range
Observation Range Approximately 15mm x 9mm
Main Unit
Built-in Printer Thermal Printer
Movable Part Movement Range Up-Down: 45mm
Right-Left: 88mm
Front-Rear: 40mm
Chin-rest Movable Range 70 mm
Data Output Type RS-232C
Display 5.7 inch color liquid crystal display
Dimension and Weight Dimension: 306 (W) x 493 (D) x 463 (H) mm
Weight: approx.18kg
Power
Voltage AC100V to 240V
Frecuency 50/60Hz
Consumption Power 85VA to 110VA
Operating Environment
Operating Temperature Range 10°C - 40°C
Humidity 30% - 75%