EZ-WOT-1800 - US Ophthalmic

K1,491,065.45


This item is currently sold out.
Includes 1 Ophthalmoscope Head, 1 Otoscope Head, Dispenser, C battery
Ophthalmoscope
The direct ophthalmoscope is used for examining the interior structures of the eyes and its background.

▪ Is available with AA alkaline or Ni-MH batteries. Bulb power: 2.5V, 1.6W.
▪ Smart design and comfortable operation
▪ Suitable for small pupil
▪ 19 lenses from 0D to ±20D: 0D, ±1D, ±2D, ±3D, ±4D, ±6D, ±8D, ±10D, ±15D, ±20D.
▪ Use with LED bulb only

ophthalmoscope pocket

Red-free filter,hemispot,small spot large spot, Fixation aperture

Otoscope

The Otoscope is used to view the tympanic membrane and external ear canal to diagnose outer and middle ear pathologies. It is the mostly used device in ENNT. Fiber optics transmit light system, the fiber optics extend to the tip of the instrument for more light output, less glare.

▪ 2.5 x magnification
▪ Reuseable Ear-Specula: 2.5mm and 4.0mm,5 for each. 3mm and 5mm for optional.
▪ Insufflation Port: view tympanic membrane using an Insufflator bulb.
▪ Smart design, convenient for mobile diagnosis.
▪ Use with LED bulb only

Ophthalmoscope
Optical Specifications
19 Various lenses ranging in power from 0D to ±20D 0D, ±1D, ±2D, ±3D, ±4D, ±6D, ±8D, ±10D, ±15D, ±20D
Aperture Red-free filter
Large spot
Small spot
Hemispot
Fixation aperture
Electrical Specification
Rated Voltage Two AA alkaline or Ni-MH batteries
Type of bulb 2.5 V / 1.6 W
Electrical Safety Standard Complying with EN60601-1 / EN60601-1-2
Protection: Internal electrical power source
Operation mode: Intermittent. 2 minutes 'ON'. 5 minutes 'OFF'
Environment Requirements
Operation Environment Temperature
Relative Humidity
Atmospheric Pressure
+10 °C - +35 °C
30% - 75%
700 hPa - 1060 hPa
Shipping Common Conveyance  
Storage Temperature
Rel. humidity
Air Pressure
-40 °C - +55 °C
10% - 90%
500 hPa - 1060 hPa

Otoscope
Optical Specifications
Illumination Fiber optics transmit light
Magnification of lens 2.5 x
Specifications of ear-specula
Diameter of ear-specula 0.10in/2.5mm, 0.16in/4mm
Specifications of insufflation Port
Insufflation Port Yes
Electrical Specification
Bulb T4954 2.5V / 1.6W
Rated Voltage Two AA alkaline or Ni-MH batteries
Operation Mode Intermittent: on time should not exceed 2 min with off-time not less than 5 min
Electrical Safety Complying with EN60601-1 / EN60601-1-2
Protection: Internal electrical power source
Type BF applied part
Environment Requirements
Operation Environment Temperature
Relative Humidity
Atmospheric Pressure
+10 °C - +35 °C
30% - 75%
700 hPa - 1060 hPa
Shipping Common Conveyance  
Storage Temperature
Re. Humidity
Air Pressure
-40 °C - +55 °C
10% - 90%
500 hPa - 1060 hPa
Ophthalmoscope
Optical Specifications
19 Various lenses ranging in power from 0D to ±20D 0D, ±1D, ±2D, ±3D, ±4D, ±6D, ±8D, ±10D, ±15D, ±20D
Aperture Red-free filter
Large spot
Small spot
Hemispot
Fixation aperture
Electrical Specification
Rated Voltage Two AA alkaline or Ni-MH batteries
Type of bulb 2.5 V / 1.6 W
Electrical Safety Standard Complying with EN60601-1 / EN60601-1-2
Protection: Internal electrical power source
Operation mode: Intermittent. 2 minutes 'ON'. 5 minutes 'OFF'
Environment Requirements
Operation Environment Temperature
Relative Humidity
Atmospheric Pressure
+10 °C - +35 °C
30% - 75%
700 hPa - 1060 hPa
Shipping Common Conveyance  
Storage Temperature
Rel. humidity
Air Pressure
-40 °C - +55 °C
10% - 90%
500 hPa - 1060 hPa

Otoscope
Optical Specifications
Illumination Fiber optics transmit light
Magnification of lens 2.5 x
Specifications of ear-specula
Diameter of ear-specula 0.10in/2.5mm, 0.16in/4mm
Specifications of insufflation Port
Insufflation Port Yes
Electrical Specification
Bulb T4954 2.5V / 1.6W
Rated Voltage Two AA alkaline or Ni-MH batteries
Operation Mode Intermittent: on time should not exceed 2 min with off-time not less than 5 min
Electrical Safety Complying with EN60601-1 / EN60601-1-2
Protection: Internal electrical power source
Type BF applied part
Environment Requirements
Operation Environment Temperature
Relative Humidity
Atmospheric Pressure
+10 °C - +35 °C
30% - 75%
700 hPa - 1060 hPa
Shipping Common Conveyance  
Storage Temperature
Re. Humidity
Air Pressure
-40 °C - +55 °C
10% - 90%
500 hPa - 1060 hPa