Accurate and Reliable Measurement
The TN-100 Air Tonometer is a device with accurate and reliable measurement. It has a soft air puff with a silent operation. It has highly accurate measurements (Measurement accuracy of 0.5mmHg) achieved with an automatic alignment that has produced a reduction in operator error.

Non Contact Tonometer tn-150 frey - us ophthalmic - us ophthalmic

Auto Alignment and Auto Shot
TN-100 is easy and intuitive to use, including inexperienced users. Alignment and measurement are automated, with simple hand adjustment of the joystick towards the patient‘s eye to commence automatic examination.

Non Contact Tonometer tn-150 frey - us ophthalmic - us ophthalmic

Cornea Thickness Corrected IOP
Users can easily adjust the measured IOP data by the value of the central corneal thickness. TN-100 has pre-programmed formulas for IOP correction. If central corneal thickness is entered before examination, the device will display corrected IOP valúes.

Non Contact Tonometer tn-150 frey - us ophthalmic - us ophthalmic

Embedded Patient Database
Patient data storage capability and measurement values for 4000 patient data base included. Patient examination record and database is available immediately upon completion of examination. Individual patient examination or entire patient history can printed with simple one touch. Internal printer simplifies record keeping.

Non Contact Tonometer tn-150 frey - us ophthalmic - us ophthalmic

SD Card
SD card can be used to backup patient results and to transfer the data to PC computer. Installation version of PC application for patient records management is delivered on SD card supplied with TN-100.

Non Contact Tonometer tn-150 frey - us ophthalmic - us ophthalmic

Multiple Patient Test Results can be Printed at Once
Large internal memory allows for secure storage patient measurement history. The operator can choose between printing last result of patient measurement or to print complete patient history stored in device memory.

Non Contact Tonometer tn-150 frey - us ophthalmic - us ophthalmic

Soft Air Puff and Silent Operation
To maximize patient comfort during the measurement, air puff has been optimized to be soft and silent.

Non Contact Tonometer tn-150 frey - us ophthalmic - us ophthalmic

Touch Screen Interface
East to use, intuitive operation of TN-100 features a 7” color LCD capacitive touch screen. User interface software is optimized for each function, clearly displaying all measurement data guiding the User through the measurement process from the alignment of the eye, to the display of the readings. TN-100 menus and device options are easily accessed and simple to navigate.

Non Contact Tonometer tn-150 frey - us ophthalmic - us ophthalmic

Electrically Driven Measurement Head and Chinrest
Electrically driven chinrest allows easy adjustment of patient position and assures stable position during IOP measurement. Wide range of measurement head movement allows measurement both eyes without need to change patient position.

Non Contact Tonometer tn-150 frey - us ophthalmic - us ophthalmic

Multifunction Joystick
Controls 3 axis movement of the measurement head. Allows user to trigger manual measurement with push button located at the top.

Non Contact Tonometer tn-150 frey - us ophthalmic - us ophthalmic

Operator Panel with Push Buttons
The operator panel with of the chinrest for Up/Down movement of the chin rest, sleep mode and packing position.
Measurement Range 0 - 60 mmHg (0 - 80hPa)
Measurement Accuracy 0.5 mmHg
Main Unit Dimensions H/W/L 460 x 300 x 480 mm
Weight 18 kg
Power Source 100-240VAC 50/60 Hz
Power Consumption Max 45VA
Power Supply Unit External, medical power supply adapter
INPUT: 100-240V ~1,5A
OUTPUT: 12V ⎓5A
Printer Built-in, thermal
Display 7" color LCD with touch screen
Chin Rest Travel Distance 69 mm (up/down)
Measuring Unit Travel Distance 85 mm (X axis); 40 mm (Y axis); 50 mm (Z axis )
Chin Rest Electrically regulated (up/down)
Storage Devices Internal flash
SD Card
Database Capacity Up to 4000 patients x 100 exams x 3 measurements (for each eye) Data format: XML