Ezer Applanation Tonometer ESL-Emerald-TN

REQUEST QUOTEor call toll-free (888) 881-1122Financing available — simple terms, no leasing. Ask about it in your quote request.

The Japanese tonometer ESL-Emerald-TN is a precision applanation tonometer designed to be mounted on slit-lamp stereoscopic microscopes, used to measure intraocular pressure (IOP).

The ESL-Emerald-TN operates by bringing the applanation measuring cone into contact with the eye and gradually applying pressure to the corneal surface until it is temporarily flattened. The measuring cone determines the force required to achieve this, providing IOP measurements that are fundamental for diagnosing or assessing a patient’s risk of glaucoma.

Thanks to its precision machining, accessibility, modular versatility, and patient comfort, the ESL-Emerald-TN is the perfect complement to slit-lamp microscopes in any clinical setting, facilitating the acquisition of IOP measurements.

Ezer Applanation Tonometer ESL-Emerald-TN

Modular versatility with multiple microscopes

Compatible with various slit lamp manufacturers, not exclusively with the ESL-Emerald system. Provides unprecedented adaptability for different clinical settings.

Maximum patient comfort

Applanation surface of only 3.06 mm in diameter minimizes corneal contact and ocular deformation. Enables rapid measurements without compromising the quality of care.

Simplified operation without complex calibration

Direct reading of results without standardization difficulties. Includes a quick reference table for converting pressure to IOP without additional software.

Precision optics manufactured in Japan

High-quality optical components with integrated cobalt filter. Ensures glare-free split-image observation for accurate intraocular pressure measurements.

Ezer Applanation Tonometer ESL-Emerald-TN – image 4
Ezer Applanation Tonometer ESL-Emerald-TN – image 5
Ezer Applanation Tonometer ESL-Emerald-TN – image 6
Ezer Applanation Tonometer ESL-Emerald-TN – image 7
Ezer Applanation Tonometer ESL-Emerald-TN – image 8
Ezer Applanation Tonometer ESL-Emerald-TN – image 9
Ezer Applanation Tonometer ESL-Emerald-TN – image 10
Ezer Applanation Tonometer ESL-Emerald-TN – image 11
Ezer Applanation Tonometer ESL-Emerald-TN – image 12
Ezer Applanation Tonometer ESL-Emerald-TN – image 13
Ezer Applanation Tonometer ESL-Emerald-TN – image 14
Ezer Applanation Tonometer ESL-Emerald-TN – image 15
Ezer Applanation Tonometer ESL-Emerald-TN – image 16

The ESL-Emerald-TN tonometer combines high-quality construction and adaptability in a compact modular device that can be mounted on a slit-lamp stereoscopic microscope used in ocular imaging.

Although this accessory was designed with the ESL-Emerald microscope system in mind, the ESL-Emerald-TN can be added to many different microscopes from various manufacturers. This allows for unprecedented versatility and its application across a wide range of clinical settings.

Ezer Applanation Tonometer ESL-Emerald-TN – image 1

With a small applanation surface of only 3.06 mm in diameter and an area of 7.35 mm², the ESL-Emerald-TN tonometer minimizes the amount of corneal contact and ocular globe deformation required to obtain a high-precision reading.

This ensures patient comfort and can help reduce time per measurement, allowing operators to maintain an efficient workflow without compromising the quality of patient care.

Ezer Applanation Tonometer ESL-Emerald-TN – image 2

The ESL-Emerald-TN tonometer is designed with user experience as the top priority. There are no calibration or standardization difficulties to worry about; simply apply pressure until applanation is achieved and read the results directly from the device. An included quick-reference table simplifies the conversion of the measuring drum pressure to IOP, with no additional software or calculations required.

High-precision, high-quality optical components are key to the performance of the ESL-Emerald-TN tonometer. The selected slit lamp illumination passes through the integrated cobalt filter before traversing the plastic measuring prism, providing split-image observation free of reflections.

Ezer Applanation Tonometer ESL-Emerald-TN – image 3

Specifications

Ezer Applanation Tonometer ESL-Emerald-TN specifications
Pressure surface 7 mm
Measuring drum surface 3.06 mm (area of 7,354 mm²)
Pressure conversion mmHg to kPa
Angular light source 60 degrees
Tonometer scale 6 calibrations
Measurement force Spring-generated
Measurement range 0 / 80 mmHg (0 / 10.64 kPa)
Weight 725 g (without accessories)
Dimensions 47 mm (width) × 30 mm (depth) × 85 mm (height)
Power supply AC 220 V 50 Hz
Power consumption 25 VA