The Luxvision LDR-7800 automated phoropter is easy to use, features customizable visual charts and vision tests, rapid lens changes, and leverages data from previous examinations, delivering easy-to-understand results.
Luxurious design meets exceptional functionality in Luxvision’s remarkably robust digital refraction unit. The LDR-7800 features real-time graphical representations displayed on screen, guiding you and your staff through the entire testing process. With countless tests to choose from, you can customize the sequences you most commonly prefer to use in clinical practice. You will also save valuable testing time, as the LDR-7800 retrieves data from previous examinations so you have an excellent starting point and basis for comparison. In addition, this cutting-edge device features a dual cross-cylinder lens and an automatic occlusion function. A touchscreen, elegant keypad, control dial, built-in printer, and more make this premium digital refraction unit a brilliant choice.
Easy-to-Use Real-Time Guide
The LDR-7800 features a real-time graphical display shown on screen that guides you and your staff through the entire testing process.

Customizable Visual Charts and Tests
The LDR-7800 features 18 visual acuity tests, 24 monocular/binocular balance tests, and 35 user-defined unit tests. While the LDR-7800 comes preprogrammed with a standard sequence, users can also define up to 10 sequences of their preference.

Leverage Pre-Exam Data
Collect data from your lensometer and auto-refractor/keratometer to use during the examination with the LDR-7800. The LDR-7800 makes it possible to organize and manage refraction in a single testing environment.

Quick Lens Change
The lens operation is fast and precise. No data will be skipped when operating the multifunctional jog shuttle dial of the device.
Dual Cross Cylinder Test
Besides the traditional Jackson cross cylinder test, the LDR-7800 features a Dual Cross Cylinder Lens. This innovative split prism lens allows you to present two images simultaneously, relieving the difficulty patients experience with the question “Which is better, one or two?”. Patients make their selection more quickly and with greater certainty. With the LDR-7800, you can easily switch between the dual cross cylinder test and the Jackson cross cylinder test.

Easy-to-Understand Results
The LDR-7800 reduces confusion among staff and patients thanks to its remarkable results format. Test results are displayed in tables and charts that help make them easier to understand.

LCD Screen and Touch Panel with Tilt
With 90° tilt and touch interface, the LCD panel is a powerful communication and programming hub. It intuitively guides professionals and staff for comfortable system operation. It also offers numerous visual testing possibilities, allowing you to define and choose programs, individual tests, and more.

Elegant Keyboard
The LDR-7800 features an elegant keyboard with well-organized keys grouped by function. Shortcut options are also available for easier operation. Countless tests and charts are available at the press of a button.

Built-in Printer
The single-step printing process allows operators to quickly print test results. Paper replacement is also simplified.

Integrated Patient Education Tools
This revolutionary Luxvision takes testing to the next level by integrating educational tools to help you explain procedures and options to your patients. A variety of image clips are included, such as a progressive lens guide, an eye diagram, and an explanation of refraction.

Seamless Network Connectivity
Connect your pre-examination equipment, additional refractors, PCs, and more for the ultimate connected environment.

Specifications
| Spherical Lens | -29.00 ~ +26.75D (Regular) -19.00 ~ +16.75D (Cross Cylinder or Prism Test) (increments of 0.12D / 0.25D / 0.5D / 1.0D / 2.0D / 3.0D / 4.0D) |
|---|---|
| Cylindrical Lens | 0.00 ~ ±8.75D (increments of 0.25D / 0.5D / 1D / 2D / 3D) |
| Cylinder Axis | 0 ~ 180° (1° / 5° / 15° increments) |
| Pupillary Distance (PD) | 1.9in/48mm ~ 3.15in/80mm (increments of 0.02in-0.5mm / 0.04in-1mm) Near Working Distance: 13.8in/350mm ~ 27.6in/700mm |
| Rotating Prism | 0 ~ 20Δ (increments of 0.1Δ / 0.2Δ / 0.5Δ / 1Δ / 2Δ) |
| Cross Cylinder | ±0.25D ±0.50D ±0.25D Split Prism Lens (Dual Cross Cylinder) |
| Retinoscope | +1.5D, +2.0D (Measurement Distance 26.4in/670mm, 19.7in/500mm) |
| Auxiliary Lens | |
| Pinhole Lens | Ø0.04in (Ø1mm) |
| Maddox Rod | Right Eye (Red, Horizontal), Left Eye (Red, Vertical) |
| Red / Green Filter | Right Eye (Red), Left Eye (Green) |
| Polarizing Filter | Right Eye: (135°, 45°), Left Eye: (45°, 135°) |
| Split Prism | Right Eye (6Δ BU) Left Eye (10Δ BI: up to 5Δ complement) |
| Fixed Cross Cylinder | (±0.50D, Fixed with axis at 90°) |
| Dimensions | |
| Refractor | 14.2(W) x 4.25(D) x 11.2(H) in, 10.34lb (361(W) x 108(D) x 280(H) mm, 4.7kg) |
| Controller | 8.5(W) x 9.7(D) x 8.85(H) in, 4.158 lb (216(W) x 246(D) x 225(H) mm, 1.89kg) (Printer included) |
| Connection Box | 9.88(W) x 9.45(D) x 2.8(H) mm, 4.136lb (251(W) x 240(D) x 71(H) mm, 1.88kg) |
| Power Supply | AC 100-120V / AC 200-240V, 50 / 60Hz |
| Power Consumption | 145VA |