Skip to content
Search
+1 (888) 881-1122 REQUEST QUOTE

Clinical Areas:

Retina and Fundus

Glaucoma and Intraocular Pressure

Myopia Control

Cataract

Ezer Digital Refractor EDR-9000 A

REQUEST QUOTEor call toll-free (888) 881-1122Financing available — simple terms, no leasing. Ask about it in your quote request.

The Ezer EDR-9000 digital refractor features a high-resolution LCD touch screen that provides functionality, comfort, and fast measurements for the optometrist. The recently redesigned Ezer EDR-9000 digital refractor offers more features than you ever thought possible—all in an incredible package designed to network with a complete digital practice platform. You will be impressed by the full range of tests, routines, and built-in units. Even better, they are fully customizable. You won’t be the only one impressed by the EDR-9000 digital refractor. Patients will notice the difference too. The EDR-9000 allows you to directly experience and compare the results of objective tests and subjective test results obtained from the EDR-9000 digital refractor. You will truly achieve speed without sacrificing precision or personal touch. No detail was overlooked in the development of the EDR-9000 digital refractor, right down to its quiet motors, fast reset, and slim compact design that eliminates any potential tunnel vision effect that some patients perceive with deeper optical heads. With its sleek keypad, 8″ tilting and screen-reversible LCD touch panel, built-in printer, and more, you cannot go wrong selecting this top-of-the-line instrument.

Ezer Digital Refractor EDR-9000 A

High-resolution LCD touchscreen

8-inch touch panel serving as an intuitive communication and programming hub. Allows defining custom programs, individual tests, and simple updates via integrated USB.

Dual cross-cylinder for greater precision

Split-lens system that allows the patient to simultaneously view the plus and minus options, eliminating confusion. Provides 1-degree access refinements for more precise and comfortable examinations.

Fully customizable examination programming

Offers 1 system program and 11 custom programs with unit test functions (30 system tests and 36 custom ones). Allows configuration of professional preferences and specific refraction step order.

Advanced objective-subjective comparison functions

Provides 6 testing modes to directly compare objective with subjective results, previous with new prescription, or daytime and nighttime vision. Eliminates patient doubts about the need for a new personalized prescription.

Ezer EDR-9000 A Digital Refractor
Ezer EDR-9000 A Digital Refractor
Ezer EDR-9000 A Digital Refractor

Dual Cross Cylinder Lenses

A Dual Cross Cylinder (split prism) allows the patient to simultaneously view the positive and negative cross cylinder lens, eliminating the need to remember which is better, 1 or 2. The examination is easier and less confusing for patients and more accurate, with 1-degree access refinements. When integrated with the Ezer ERK 9000 autorefractor/keratometer, very little refinement is required for most patients.

Ezer Digital Refractor EDR-9000 A

Ezer Digital Refractor EDR-9000 A – image 1

Advanced Engineering

The advanced design incorporates high-quality motors that switch quickly and reduce noise when changing lenses, ensuring many years of reliable operation.

Ezer Digital Refractor EDR-9000 A – image 2

Take Control

It is time to replace the standard phoropter with the recently redesigned and intuitively designed EDR-9000 electronic refraction technology. The EDR-9000 allows you to take control of the refraction process in ways you never imagined. You can fully program your preferences into the EDR-9000 so that you or your technicians can reliably perform the refraction steps in a specific order.

Ezer Digital Refractor EDR-9000 A – image 3

Complete set of patient education charts and special tests

When integrated with the Ezer ECP 5400, the EDR 9000 offers the operator more patient education charts, special tests, and color charts than any refraction system currently on the market, putting greater diagnostic efficiency at your fingertips.

Ezer Digital Refractor EDR-9000 A – image 4

Objective and Subjective Comparison Functions

The Ezer EDR-9000 also offers 6 test modes that allow you to quickly compare your objective test results and multiple subjective test results for final change verification. For example, the operator can quickly compare the previous Rx with the new Rx, or daytime and nighttime vision corrections, which will eliminate the patient’s doubts about their need for a new and personalized prescription.

Ezer Digital Refractor EDR-9000 A – image 5

Visual Charts and Tests

The EDR-9000 offers globally standardized charts. With a built-in System Program and 11 Custom Programs and Unit Test Functions (30 System Tests and 36 Custom Programs), the possibilities are endless. Professionals can fully control the examination according to their professional preference.

Ezer Digital Refractor EDR-9000 A – image 6

Comparison Functions

The EDR-9000 also offers 6 test modes that allow you to directly compare your objective test results with the subjective test result. The convenient Comparison Mode allows you to directly observe how the subjective vision test results differ from those measured by the Ref/Keratometer and the Lensometer.

Ezer Digital Refractor EDR-9000 A – image 7

Touchscreen Interface

The 8″ LCD touch panel is a powerful communication and programming hub, allowing you to define and select programs, unit tests, and more. It intuitively guides professionals and staff for comfortable system operation. Custom updates are also simple via the built-in USB.

Ezer Digital Refractor EDR-9000 A – image 8

High-Resolution Color LCD Panel with Screen Tilt and Inversion

With 180° tilt and touch interface, the high-resolution color LCD panel also offers numerous visual testing possibilities, allowing you to accurately perform color blindness tests and evaluate near vision through built-in charts and images.

Ezer Digital Refractor EDR-9000 A – image 9

Elegant and Easy-to-Use Keyboard

The Ezer EDR-9000 features an elegant keyboard with well-organized keys grouped by function. Shortcut options are also available for greater ease of use. An 8-inch LCD touch panel puts chart selection, and many other efficiency functions, at your fingertips.

Ezer Digital Refractor EDR-9000 A – image 10

Built-in Printer

The single-step printing process allows operators to quickly print test results. Paper replacement is also simplified.

Ezer Digital Refractor EDR-9000 A – image 11

Compatible Connection with Various Systems

It is possible to connect multiple chart devices (ECP-5400, ERK 9000, and PCs) with a single cable. It is recommended that owners also use the ERK-9000 to take full advantage of the possible functionality with the EDR-9000.

Ezer Digital Refractor EDR-9000 A – image 12

Simultaneous Data Sharing

The EDR-9000 makes it possible to organize and manage refraction in a single testing environment. At last, sharing data is cost-effective thanks to maximum product compatibility centered on the powerful and robust EDR-9000.

Ezer Digital Refractor EDR-9000 A – image 13

Ezer Digital Refractor EDR-9000 A videos

Video: Digital Practice Ezer
Video: Overview - Digital Refractor EDR-9000
Video: Display - Digital Refractor EDR-9000
Video: Keyboard - Digital Refractor EDR-9000
Video: Patient Set up - Digital Refractor EDR-9000
Video: Performing - Digital Refractor EDR-9000

Specifications

Ezer Digital Refractor EDR-9000 A specifications
Measurement Range
Spherical Lens -29.00 ~ +26.75D (Regular) -19.00 ~ +16.75D (Cross Cylinder, Prism Test) (Step: 0.12D / 0.25D / 0.5D / 1D / 2D / 3D)
Cylindrical Lens 0.00 ~ 8.75D (Step: 0.25D / 0.5D / 1D / 2D / 3D)
Cylinder Axis 0 ~ 180° (Step: 1° / 5° / 15° / 30° / 45°)
Pupillary Distance Far 2 ~ 3.15in (48 ~ 80mm) Near 1.8 ~ 3in (45 ~ 75mm) (Step: 0.019 / 0.039in (0.5 / 1.0 mm))
Working Distance 14 ~ 28in (350 ~ 700mm) (Step: 2in (50 mm))
Rotating Prism 0 ~ 20Δ (Step: 0.1Δ / 0.2Δ / 0.5Δ / 1Δ / 2Δ)
Cross Cylinder Jackson Cross Cylinder ± 0.25D Jackson Cross Cylinder ± 0.50D Dual Jackson Cross Cylinder
Retinoscopy Lens +1.5D, +2.0D (Test Distance 24in, 20in (670mm, 500mm))
Specifications
Body 14(W) x 4(D) x 11.7(H) in, 7.7lb (362(W) x 82(D) x 299(H) mm, 3.5Kg)
Controller 8.4(W) x 9(D) x 8.9(H) in, 3.3lb (215(W) x 230(D) x 226(H) mm, 1.5Kg)
Connection Box 10.5(W) x 2.4(D) x 9.4(H) mm, 2.2lb (266(W) x 60(D) x 239(H) mm, 1.0Kg)
Power Supply AC 100 ~ 240V, 50 / 60 Hz
Power Consumption 90VA
Auxiliary Lenses
Lens Open / Close Open / Close Selection
Pinhole Lens Ø0.04in (1mm)
Maddox Rod Right Eye (Red Horizontal), Left Eye (Red Vertical)
Red / Green Filter Right Eye (Red), Left Eye (Green)
Polarized Light Filter Right Eye (135°, 45°), Left Eye (45°, 135°)
Separation Prism Right Eye (6ΔBU), Left Eye (10ΔBI can be added from 0 ~ 5Δ)
Trial Lens PD On / Off Selection
Fixed Cross Cylinder Lens Jackson Cross Cylinder ±0.50D, Axis Lock 90°
Degrees of Vision 32°
Designs and details may change without prior notice for improvement purposes.

Manuals & Catalogs

Catalogs

Ezer Digital Refractor EDR-9000 A

Ezer Digital Refractor EDR-9000 A – catalog cover
Manuals

Ezer Digital Refractor EDR-9000 A

Ezer Digital Refractor EDR-9000 A – manual cover