Skip to content
Search
+1 (888) 881-1122 REQUEST QUOTE

Clinical Areas:

Retina and Fundus

Glaucoma and Intraocular Pressure

Myopia Control

Cataract

Huvitz Slit Lamp HIS-5000 5X

REQUEST QUOTEor call toll-free (888) 881-1122Financing available — simple terms, no leasing. Ask about it in your quote request.

The Huvitz HIS-5000 5X 10M slit lamp microscope offers fast and precise diagnosis, with acquisition, storage, and retrieval of perfect images, along with all patient data.

Huvitz, a leading manufacturer of slit lamps and world-class optics designer, presents the HIS-5000 5X 10M Slit Lamp. This powerful unit features a high-performance progressive scan CCD camera that displays high-resolution images in real time. It also offers a robust image processing and data management system that assists with diagnosis, clinical recordkeeping, and information sharing.

The HIS-5000 5X 10M is a Haag-Streit style slit lamp with tower illumination, equipped with a convergent Galilean binocular optical system and a five-position drum-type magnification selector, providing an exceptional zoom range from 6x to 40x. A high-luminance halogen lamp ensures the purest image quality, which can be viewed through five illumination filters, including yellow. From design to production, the Huvitz HIS-5000 5X 10M is exceptional.

ℹ Available with Halogen and LED Illumination.

Huvitz Slit Lamp HIS-5000 5X

Advanced high-precision optics

The high-quality optical system provides sharp and detailed images, enabling precise analysis of anterior ocular structures.

Powerful and adjustable LED illumination

High-intensity LED light source with precise slit control, ensuring excellent visualization under varying clinical conditions.

Versatile magnification with multiple levels

The magnification system offers different zoom levels, allowing greater flexibility during detailed ophthalmic examinations.

Precise Control and Smooth Movement

Ergonomic joystick mechanism allows fine and stable adjustments, facilitating positioning and increasing examination precision.

Huvitz Slit Lamp HIS-5000 5X – image 15
Huvitz Slit Lamp HIS-5000 5X – image 16
Huvitz Slit Lamp HIS-5000 5X – image 17
Huvitz Slit Lamp HIS-5000 5X – image 18
Huvitz Slit Lamp HIS-5000 5X – image 19
Huvitz Slit Lamp HIS-5000 5X – image 20

“See the difference…”

Intuitive and easy-to-use information management and processing.
The illumination system provides an extremely bright and vivid view

This Haag-Streit tower-style slit lamp uses a 12-volt, 30-watt high-luminance halogen lamp to deliver the purest image possible.

Huvitz Slit Lamp HIS-5000 5X – image 1

Magnification control system for diverse observations

The Huvitz optical system, exclusively designed, eliminates image distortion at all magnification levels, enabling more precise diagnosis. The five-position drum-type magnification selector provides easy access to magnifications from 6x to 40x.

Huvitz Slit Lamp HIS-5000 5X – image 2

A faster and more stable digital camera

The HIS-5000 5X 10M delivers high-resolution 10-megapixel images through an IEEE 1394 interface, which performs image data transfer faster and with greater stability compared to the conventional USB interface method.

Huvitz Slit Lamp HIS-5000 5X – image 3

Easy-to-use microscope

The HIS-5000 5X 10M features a convergent Galilean binocular optical system that delivers vivid images and a wide field of view. The operator can select total magnifications equivalent to 6x (∅38,5 mm), 10x (∅22,2 mm), 16x (∅15,2 mm), 25x (∅10,5 mm) and 40x (∅6,7 mm).

Huvitz Slit Lamp HIS-5000 5X – image 4

Integrated control

The omnidirectional-style joystick is easy to control. An integrated trigger button allows comfortable image and video capture. When connected to imaging devices, the slit lamp enables simultaneous storage of images and videos.

Huvitz Slit Lamp HIS-5000 5X – image 5

Illumination control with ergonomic design

The illumination lever is conveniently located next to the joystick. The brightness selector can be adjusted to High or Normal, making diagnostic procedures even simpler.

Huvitz Slit Lamp HIS-5000 5X – image 6

Five filters, including yellow

Five filters integrated into the illumination system can be easily inserted using the selection lever. Options include: heat absorption filter for greater patient comfort during prolonged examinations; red-free filter to enhance structural contrast; cobalt blue filter for fluorescein evaluation; grey filter; and yellow filter to absorb blue light and increase contrast.

Huvitz Slit Lamp HIS-5000 5X – image 7

Available with LED or Halogen Light Source

This slit lamp is now available in LED or Halogen versions. LED lighting technology offers a sharper, brighter, and more uniform slit compared to conventional illumination. The shorter wavelength of LED light ensures visualization of structures with a higher level of detail. Additionally, LED illumination provides energy savings and cost reduction, significantly decreasing the need for lamp replacement.

Easy-to-Use Patient Information Management

The MS Access database-based system allows you to easily search and manage both previous and current data for all your patients.

Intuitive interface

A tree-structure interface helps users quickly access information, without complicated multi-step clicks.

Huvitz Slit Lamp HIS-5000 5X – image 8

Fast Real-Time Image Capture

The high-performance progressive scan CCD camera displays captured images in real time.

Powerful Image Processing

The HIS-5000 5X 10M supports JPG, TIFF, RAW, and many other image formats. Operators can access them in the unit’s Live Tool image library and adjust them as needed: brightness, contrast, color channels, saturation, inversion, sharpness, red-free filter, and more.

Huvitz Slit Lamp HIS-5000 5X – image 9

Diagnose, Consult, Document and Share

[Compare]
Users can apply various effects to images. For example, selected images can be enlarged, reduced and rotated for precise comparison and diagnosis.

Huvitz Slit Lamp HIS-5000 5X – image 10

[Overlay]
The ability to compare images captured at different times allows for progression detection.

Huvitz Slit Lamp HIS-5000 5X – image 11

[Slideshow]
All images can be selected for use in presentations and slideshows.

Huvitz Slit Lamp HIS-5000 5X – image 12

[Reference]
Easily locate multiple images of the same finding for future reference.

Huvitz Slit Lamp HIS-5000 5X – image 13

[Report Generation]
Automatically export patient reports in MS Word format.

Huvitz Slit Lamp HIS-5000 5X – image 14

[Print]
One-click image printing.

The price does not include the computer shown in the images. The item includes only: slit lamp, camera, fiber optic background illumination, and software.

Specifications

Huvitz Slit Lamp HIS-5000 5X specifications
Slit length (mm) 0.3~14
Slit Width (mm) 0–14 continuous
Slit projection 1x
Aperture diaphragms 0.02 / 0.04 / 0.11 / 0.19 / 0.4 / 0.47 inches (0.3 / 1 / 3 / 5 / 9 / 12mm)
Filters Cobalt blue, red-free, yellow, grey and heat absorption
Slit rotation 0°~180° continuous
Light source LED or halogen lamp option
Patient's Eye / Prism
Angle of incidence 0°, 5°, 10°, 15°, 20°
Working distance from the surface 3.14 inches (80mm)
Microscope
Microscope 5 steps
Type Convergent Galilean Binocular
Magnification 5-position rotating drum
Eyepieces 12.5x
Total Magnification 6x, 10x, 16x, 25x, 40x
Real visual fields (mm) 38.5, 22.2, 15.2, 10.5, 6.7
Interpupillary adjustment 2.16 in ~3.14 in (55mm~80mm)
Base
Vertical Movement 1.10 inches (28mm)
Longitudinal Movement 3.07 inches (78mm)
Lateral Movement 3.85 inches (98mm)
Thin Base 0.4 inches (10mm)
Power supply Free voltage 100~240 V AC
Voltage Frequency 50/60Hz
Power Consumption 70VA
Instrument voltage 12V DC
Halogen lamp 12V 30W
Fixation point lamp 3.4V 20mA
Digital camera
Image sensor 1/2" CMOS
Image size up to 3840 x 2748 pixels
Cell size 1.67 µm x 1.67 µm
Transmission Method USB 2.0
Transmission speed 480Mbps
Frame rate Maximum 30fps
Lens mount C-Mount
Power consumption 2.5W
CPU (Central Processing Unit) Pentium IV, 2GHz
Memory 512 MB (Recommended: above 1 GB)
Video card ATI Radeon 9200 (128MB) or similar
System Microsoft Windows NT (with Service Pack 6), Windows 2000 (with Service Pack 4)
Transmission Method Windows XP, Microsoft Internet Explorer 6 (Explorer 7 recommended) Standard FireWire IEEE 1394a port compatible with OHCI 1.1 (with 12 V auxiliary power connector if connected to a laptop)
Display Monitor: LCD or CRT (minimum resolution 1.280 × 1.024 pixels, recommended above 1.600 × 1.200 pixels)
OPTION: PC, table — Designs and details may be modified without prior notice for improvement purposes.

Manuals & Catalogs

Catalogs

Huvitz Slit Lamp HIS-5000 5X

Huvitz Slit Lamp HIS-5000 5X – catalog cover
Manuals

Huvitz Slit Lamp HIS-5000 5X

Huvitz Slit Lamp HIS-5000 5X – manual cover