HBM-1 (MD)
HBM-1 (MD)
HBM-1 (MD)
HBM-1 (MD)
Load image into Gallery viewer, HBM-1 (MD)
Load image into Gallery viewer, HBM-1 (MD)
Load image into Gallery viewer, HBM-1 (MD)
Load image into Gallery viewer, HBM-1 (MD)
This item is currently sold out.
HBM-1: Optical Biometry with Full Corneal Topography System
HBM-1 is an advanced ophthalmic diagnostic platform designed to support a wide range of clinical needs, from myopia progression management and corneal analysis to contact lens fitting and dry eye assessment. Leveraging accurate, data-driven insights, it provides an objective assessment of each patient's ocular health, helping practitioners build tailored diagnosis and treatment strategies. Its clear, all-in-one reports streamline workflows while improving diagnostic precision.
biometer hbm-1 MD

MYOPIA

Smart, Data-Driven Myopia Management

The HBM-1 delivers a comprehensive approach to myopia management by visualizing changes in axial length (AL) and refraction over time. Longitudinal progression data is presented through intuitive graphs, while refraction (Rx) data transferred from Huvitz refractors can be integrated to support clinical decision-making. Clinicians can evaluate and present treatment outcomes, compare pre- and post-treatment changes associated with orthokeratology lens wear and surgical interventions, assess anisometropia, and offer more personalized patient consultations.

biometer hbm-1 md
Axial Length Progression Analysis

Visualize changes in axial length and growth rates over time to gain a clear understanding of myopia progression and treatment effectiveness.

biometer hbm-1 md
Ocular Growth Assessment Using Age-Based Growth Curves

Compare patient data against age-specific percentile growth curves to evaluate ocular growth patterns and assess the risk of myopia progression.

Personalized Myopia Management and Treatment Analysis

Track treatment history and duration while comparing changes before and after orthokeratology treatment. By evaluating anisometropia and lifestyle-related risk factors alongside progression data, the HBM-1 helps clinicians develop individualized myopia management and treatment strategies.

biometer hbm-1 md
biometer hbm-1 iol

TOPOGRAPHY

Comprehensive Corneal Analysis in a Single Scan

Using Placido disc-based topography technology, the HBM-1 precisely measures a wide range of corneal parameters — including keratometry, keratoconus indices, Zernike coefficients, pupillometry, and White-to-White. Together, these measurements enable accurate assessment of corneal shape and visual quality, supporting contact lens fitting, early keratoconus detection, and both refractive and cataract surgery planning.

biometer hbm-1 md
Accurate Keratometry and Comprehensive Corneal Assessment

Leveraging advanced Placido disc analysis technology, the HBM-1 provides the precise keratometry values (K1 and K2) essential for IOL power calculation. It also delivers comprehensive corneal maps and measurement data — including axial, tangential, refractive power, and elevation maps — enabling detailed evaluation of the entire cornea.
Measured Parameters: Keratometry, Topography, Keratoconus, Zernike Coefficients, Pupillometry, White-to-White

biometer hbm-1 md
biometer hbm-1 md
Immediate Contact Lens Fitting Evaluation

With its Fluorescein Image Filter, the HBM-1 simulates fluorescein patterns without applying fluorescein dye directly to the eye. This allows immediate evaluation of both hard and soft contact lens fitting, improving clinical efficiency and patient comfort.

biometer hbm-1 md
Early Keratoconus Detection

The HBM-1 calculates the Keratoconus Prediction Index (KPI) to support the early detection and assessment of keratoconus, enabling timely clinical intervention and management.

biometer hbm-1 md
Advanced Zernike Analysis

By analyzing Zernike coefficients and maps, the HBM-1 delivers a systematic evaluation of higher-order aberrations, refractive variations, and irregular astigmatism. This comprehensive analysis supports a deeper understanding of visual quality and corneal optical performance.

DRY EYE

A Three-Step Diagnostic Workflow — OSDI · Advanced Examination · Integrated Reporting

The HBM-1 offers a structured approach to dry eye assessment, beginning with the globally recognized OSDI questionnaire to quantify patient-reported symptoms. Advanced examinations follow — including non-contact tear film stability assessment via NIBUT, lipid layer imaging, quantitative tear meniscus height analysis, and meibomian gland function grading. The objective data gathered from both the questionnaire and clinical examinations supports differential diagnosis, treatment planning, patient counseling, and long-term record management.

STEP01
biometer hbm-1 md
Enhanced Diagnostic Efficiency with the OSDI Questionnaire

The Ocular Surface Disease Index (OSDI) is a standardized questionnaire widely used to evaluate dry eye symptoms. It enables quantitative assessment of patient-reported symptoms and supports multiple languages, helping improve diagnostic efficiency while providing consistent evaluation criteria across diverse clinical settings.

STEP02

Comprehensive Evaluation Through Four Advanced Diagnostic Assessments.

biometer hbm-1 md
Meibomian Gland Dysfunction Assessment Through Visual Grading

Meibomian gland function can be visually evaluated and graded, providing valuable insight for identifying the underlying causes of dry eye disease and establishing appropriate treatment strategies.

biometer hbm-1 md
Evaporative Dry Eye Assessment Through Inter-Blink Interval Analysis

The Inter-Blink Interval (IBI) is measured to evaluate blinking patterns. Results are presented as quantitative indicators of blink frequency and regularity, supporting dry eye assessment and lifestyle-related patient counseling.

biometer hbm-1 md
Evaporative Dry Eye Assessment Through Inter-Blink Interval Analysis

Tear film stability is evaluated using a non-contact method, with areas of tear film breakup tracked in real time. The results provide quantitative visualization of both the timing and extent of breakup.

biometer hbm-1 md
Tear Meniscus Height Analysis for Tear Volume Assessment

Tear meniscus height is quantitatively measured to objectively assess tear volume. The tear meniscus can be clearly visualized along the eyelid margin and accurately measured using the built-in caliper tool. Once the measurement points are selected, the tear meniscus height is calculated automatically.

STEP03
biometer hbm-1 md
Integrated Analysis for Personalized Treatment Strategies

The Dry Eye Report consolidates the results of every assessment category — including NIBUT, Fluorescein Imaging, Lipid Layer Analysis, Tear Meniscus Height, Meibography, Blink Analysis, and OSDI — into a comprehensive, structured report optimized for diagnosis, treatment planning, and patient communication.

User Convenience

biometer hbm-1 md
Network in Huvitz Integrated Image Server (HIIS-1)
biometer hbm-1 md
Comprehensive Reports for Reliable Clinical Evaluation

The HBM-1 generates structured reports that present predicted IOL power alongside key data from Biometry, Topography, Myopia, and IOL analysis, supporting reliable clinical evaluation and decision-making.

Visual and Voice Guidance for Enhanced Patient Comfort

To improve patient comfort during examinations, the HBM-1 provides visual and voice guidance that indicates when patients should open or close their eyes throughout the measurement process.

• Measurement Start Notification (Single Beep): Indicates when the patient should open their eyes.
• Measurement Completion Notification (Double Beep): Indicates when the patient may close their eyes.

Auto Tracking for Enhanced Accuracy and Reduced Measurement Errors

The automatic focusing mechanism continuously tracks the measurement target, eliminating the inconvenience of manual focusing while enabling faster, more accurate measurements. An Auto Tracking guide also provides directional cues for joystick and chinrest adjustments, helping operators position patients more efficiently.

Integrated PC Architecture for Space and Cost Efficiency

With its integrated PC architecture, the HBM-1 eliminates the need for an external computer. Every function — from measurement and analysis to report generation — runs directly on the built-in 10.1-inch touchscreen LCD, helping save both workspace and installation costs.

HBM-1 (MD)· Configurations

Key Differences

Compare the IOL Model and the MD Model across measurement, dry eye, analysis, IOL calculation, and connectivity.

Category Function IOL Model MD Model
MeasurementAxial Length
CCT
ACD
LT
Keratometry
Topography
Keratoconus Screening
Zernike
Pupillometry
Kappa Angle, Chord mu
WTW
Dry EyeMeibomian gland
Tear Meniscus
NIBUT
Questionnaire
Blink Analysis
AnalysisContact Lens Fitting
Myopia Management
IOL CalculationIOL Calculation
Barrett Formulas
ConnectivityHIIS-1
DICOM
Standard Available as an optional license Not supported
Biometry
Parameter Measuring Range SD of Repeatability
Axial Length 0.55 - 1.58 in (14 – 40 mm) ±0.0009 in (±0.025 mm)
Keratometry
Parameter Measuring Range SD of Repeatability
Corneal Curvature Radius 0.19 - 0.51 in (5 – 13 mm) ±0.001 in (±0.03 mm)
Cornea Refractive Power 25.96D ~ 67.50D
(Diopter, n = 1.3375)
-
Direction of Principal Meridians Measuring range: 1° – 180°
Accuracy: according to the ISO 10343:2014
R1-R2≤0.3mm: ±4°
R1-R2>0.3mm: ±2°
-
White-to-white distance 7–14 mm ±0.05 mm
Pupil diameter 0.5–10 mm ±0.05 mm
Corneal Topography
Working Distance 3.14 in (80 - 100 mm)
Placido Disc 24 rings
Points Analyzed Over 100,000
Biometry (Anterior) - Option
Parameter Measuring Range SD of Repeatability
Anterior chamber depth 1.5 – 6.5 mm ±0.04 mm
Central corneal thickness 0.25 – 1.3 mm ±0.02 mm
Crystalline lens thickness 1.5–6.5 mm (phakic), 0.5–3.5 mm (pseudo-phakic) ±0.06 mm
Etc
Dry eye function - Option Tear Meniscus, NIBUT, Meibomian, Blink Analysis, Questionnaire
IOL calculator – Option General, Post Refractive, Toric
Common
Display Tiltable 10.1 inch, Touch panel color LCD
Horizontal Movement 55 mm (back and forth), 100 mm (left and right)
Vertical Movement 1.18 in / 30 mm
Chinrest Movement 2.44 in / 62 mm (up and down), motorized
Auto tracking X,Y for positioning, Z for working distance
Power consumption AC 100 - 240 V, 50/60 Hz, 1.6 - 0.7 A
PC Built in computer
Dimension 312(W) × 553(D) × 518(H) mm
Weight 48.4 lb (22 kg)

    Recently viewed