EZ-OTO-1200 ION - US Ophthalmic
EZ-OTO-1200 ION - US Ophthalmic
EZ-OTO-1200 ION - US Ophthalmic
EZ-OTO-1200 ION - US Ophthalmic
EZ-OTO-1200 ION - US Ophthalmic
EZ-OTO-1200 ION - US Ophthalmic
EZ-OTO-1200 ION - US Ophthalmic
EZ-OTO-1200 ION - US Ophthalmic
Load image into Gallery viewer, EZ-OTO-1200 ION - US Ophthalmic
Load image into Gallery viewer, EZ-OTO-1200 ION - US Ophthalmic
Load image into Gallery viewer, EZ-OTO-1200 ION - US Ophthalmic
Load image into Gallery viewer, EZ-OTO-1200 ION - US Ophthalmic
Load image into Gallery viewer, EZ-OTO-1200 ION - US Ophthalmic
Load image into Gallery viewer, EZ-OTO-1200 ION - US Ophthalmic
Load image into Gallery viewer, EZ-OTO-1200 ION - US Ophthalmic
Load image into Gallery viewer, EZ-OTO-1200 ION - US Ophthalmic

ден18,087.17 ден18,976.70


ден18,087.17


Hurry, only 5 item(s) left in stock!
10 visitors are looking this product!

Ophthalmoscope and Otoscope Diagnostics, Handle and Zipper Bag Set EZ-OTO-1200 Ezer - US Ophthalmic
In addition to examination of the fundus, the ophthalmoscope is a useful diagnostic aid in studying other ocular structures. The light beam can be used to illuminate the cornea and the iris for detecting foreign bodies in the cornea and irregularities of the pupil.

With 19 different lenses, including 0D to ±20D: 0D, ±1D, ±2D, ±3D, ±4D, ±6D, ±8D, ±10D, ±15D, ±20D, you’ll have everything you need, right at your fingertips.

There is a wide range of practical apertures and filters to select from ophthalmoscopes: small spot, large spot, hemispot, red-free filter, and fixation aperture. This selection of apertures covers all the practitioner’s basic needs in an ophthalmoscope.

Ophthalmoscope and Otoscope Diagnostics, Handle and Zipper Bag Set EZ-OTO-1200 Ezer - US Ophthalmic
Reduced Glare from a Brighter Source
Achieve improved views With the help of a fiber optics light transmitting system. Light projects from the tip of the otoscope with reduced glare are increased clarity. The ergonomic handle grants continuous brightness control while remaining comfortable for the user to hold for extended periods of time.

With a sealed system and 2.5x magnification, the otoscope allows for pneumatic otoscopy and accurate diagnosis of the otitis media. A swiveling wide-angle lens was created to be flexible for examination.



Ophthalmoscope and Otoscope Diagnostics, Handle and Zipper Bag Set EZ-OTO-1200 Ezer - US Ophthalmic

For convenience, otoscopes use disposable ear specula. With the Otoscope you can use speculations of different sizes: 2.5mm and 4.0mm. The selection of an appropriately sized specula is critical to ensuring proper use of the device and patient comfort. Younger patients who will have a narrow ear canal, select a smaller specula with a narrow profile. For adult patients, a wider specula can be used.


Ophthalmoscope ez-oph-1800 ezer

Worry-free continuous use
The single-cell polymer battery charger is designed to charge one handle. You can see that the battery is charging and how much charge it has thanks to the LED.

A visual battery indicator shows the power level at a glance and a color-coded battery indicator lets the user know when the model is fully charged and ready for use. Keep in mind that you'll never have to worry about your battery running out during your exam with an attractive charging base that is sufficiently space-saving as to fit on any desk.

Fiber Otoscope Set ez-otc-1800 ezer
Motile Equipment for Mobile Care
Completely cordless, the battery operated handle allows physicians to move room to room and floor to floor for excellent patient care on the go. Transport the instrument and multiple disposable otoscope tips in a sleek and sturdy travel case.

Ophthalmoscope
Optical Specifications
Diopter (D) 0D, ±1D, ±2D, ±3D, ±4D, ±6D, ±8D, ±10D, ±15D, ±20D
Aperture Red-free filter
Large spot
Small spot
Hemispot
Fixation aperture
Electrical Specification
Rated Voltage Two AA alkaline or Ni-MH batteries
Type of bulb 2.5 V / 1.6 W
Electrical Safety Standard Complying with EN60601-1 / EN60601-1-2
Protection: Internal electrical power source
Operation mode: Intermittent. 2 minutes 'ON'. 5 minutes 'OFF'
Environment Requirements
Operation Environment Temperature
Relative Humidity
Atmospheric Pressure
+10 °C - +35 °C
30% - 75%
700 hPa - 1060 hPa
Shipping Common Conveyance  
Storage Temperature
Rel. humidity
Air Pressure
-40 °C - +55 °C
10% - 90%
500 hPa - 1060 hPa

Otoscope
Optical Specifications
Illumination Fiber optics transmit light
Magnification of lens 2.5 x
Specifications of ear-specula
Diameter of ear-specula 0.10in/2.5mm, 0.16in/4mm
Specifications of insufflation Port
Insufflation Port Yes
Electrical Specification
Bulb T4954 2.5V / 1.6W
Rated Voltage Two AA alkaline or Ni-MH batteries
Operation Mode Intermittent: on time should not exceed 2 min with off-time not less than 5 min
Electrical Safety Complying with EN60601-1 / EN60601-1-2
Protection: Internal electrical power source
Type BF applied part
Environment Requirements
Operation Environment Temperature
Relative Humidity
Atmospheric Pressure
+10 °C - +35 °C
30% - 75%
700 hPa - 1060 hPa
Shipping Common Conveyance  
Storage Temperature
Re. Humidity
Air Pressure
-40 °C - +55 °C
10% - 90%
500 hPa - 1060 hPa

Charger
Electrical Specifications
Input Voltage 5VDC
Input Power 3VA + 15%
Lithium Battery Specifications 3.7V
Charging Port 2
Maximum Charge Time <=3.5h
Electrical Safety Complying with EN60601-1 / EN60601-1-2
Protection: Class II IPX0
Insufflation Port Yes
Power Adapter Specification
Type UE15WCPP1-050200SPA
Input 100 VAC - 240 VAC
50 Hz / 60 Hz
Input Power <=15 VA
Output 5 VDC / 2 A
Electrical Safety Complying with EN60601-1 / EN60601-1-2
Protection: Class II IP20
Environment Requirements
Operation Environment Temperature
Relative Humidity
Atmospheric Pressure
+10 °C - +35 °C
30% - 75%
700 hPa - 1060 hPa
Shipping Common Conveyance  
Storage Temperature
Re. Humidity
Air Pressure
-40 °C - +55 °C
10% - 90%
500 hPa - 1060 hPa
Ophthalmoscope
Optical Specifications
Diopter (D) 0D, ±1D, ±2D, ±3D, ±4D, ±6D, ±8D, ±10D, ±15D, ±20D
Aperture Red-free filter
Large spot
Small spot
Hemispot
Fixation aperture
Electrical Specification
Rated Voltage Two AA alkaline or Ni-MH batteries
Type of bulb 2.5 V / 1.6 W
Electrical Safety Standard Complying with EN60601-1 / EN60601-1-2
Protection: Internal electrical power source
Operation mode: Intermittent. 2 minutes 'ON'. 5 minutes 'OFF'
Environment Requirements
Operation Environment Temperature
Relative Humidity
Atmospheric Pressure
+10 °C - +35 °C
30% - 75%
700 hPa - 1060 hPa
Shipping Common Conveyance  
Storage Temperature
Rel. humidity
Air Pressure
-40 °C - +55 °C
10% - 90%
500 hPa - 1060 hPa

Otoscope
Optical Specifications
Illumination Fiber optics transmit light
Magnification of lens 2.5 x
Specifications of ear-specula
Diameter of ear-specula 0.10in/2.5mm, 0.16in/4mm
Specifications of insufflation Port
Insufflation Port Yes
Electrical Specification
Bulb T4954 2.5V / 1.6W
Rated Voltage Two AA alkaline or Ni-MH batteries
Operation Mode Intermittent: on time should not exceed 2 min with off-time not less than 5 min
Electrical Safety Complying with EN60601-1 / EN60601-1-2
Protection: Internal electrical power source
Type BF applied part
Environment Requirements
Operation Environment Temperature
Relative Humidity
Atmospheric Pressure
+10 °C - +35 °C
30% - 75%
700 hPa - 1060 hPa
Shipping Common Conveyance  
Storage Temperature
Re. Humidity
Air Pressure
-40 °C - +55 °C
10% - 90%
500 hPa - 1060 hPa

Charger
Electrical Specifications
Input Voltage 5VDC
Input Power 3VA + 15%
Lithium Battery Specifications 3.7V
Charging Port 2
Maximum Charge Time <=3.5h
Electrical Safety Complying with EN60601-1 / EN60601-1-2
Protection: Class II IPX0
Insufflation Port Yes
Power Adapter Specification
Type UE15WCPP1-050200SPA
Input 100 VAC - 240 VAC
50 Hz / 60 Hz
Input Power <=15 VA
Output 5 VDC / 2 A
Electrical Safety Complying with EN60601-1 / EN60601-1-2
Protection: Class II IP20
Environment Requirements
Operation Environment Temperature
Relative Humidity
Atmospheric Pressure
+10 °C - +35 °C
30% - 75%
700 hPa - 1060 hPa
Shipping Common Conveyance  
Storage Temperature
Re. Humidity
Air Pressure
-40 °C - +55 °C
10% - 90%
500 hPa - 1060 hPa

Recently viewed