MWRS - US Ophthalmic
MWRS - US Ophthalmic
MWRS - US Ophthalmic
MWRS - US Ophthalmic
MWRS - US Ophthalmic
MWRS - US Ophthalmic
MWRS - US Ophthalmic
MWRS - US Ophthalmic
Load image into Gallery viewer, MWRS - US Ophthalmic
Load image into Gallery viewer, MWRS - US Ophthalmic
Load image into Gallery viewer, MWRS - US Ophthalmic
Load image into Gallery viewer, MWRS - US Ophthalmic
Load image into Gallery viewer, MWRS - US Ophthalmic
Load image into Gallery viewer, MWRS - US Ophthalmic
Load image into Gallery viewer, MWRS - US Ophthalmic
Load image into Gallery viewer, MWRS - US Ophthalmic

$63,753.89


Hurry, only 1 item(s) left in stock!
10 visitors are looking this product!

wireless adaptive refractor visionfit adaptica - us ophthalmic


The Mobile Wireless Refraction System (MWRS) included 2WIN, VisionFit. The 2Win is extremely fast and will significantly enhance office efficiency. It can also be used for vision screening where large numbers of people need to be evaluated in a short period of time. A complete binocular evaluation can be performed in less than 15 seconds. The VisionFit is an innovative electronic, tunable, all-in one, solid state, mobile and wearable system of lenses. It performs a subjective sight examination and it effectively replaces both the trial glasses and the manual/electronic phoropter functionality. Includes an electronical trial frame SC, ergonomic headband, battery back, user’s manual, aluminum carry case.


How works Mobile Wireless Refraction System (MWRS)?
The 2WIN catches the objective refraction of the patient, it sends data to the tablet controlling the VisionFit that automatically sets according to the 2WIN’s values to test the subjective refraction.

wireless adaptive refractor visionfit adaptica - us ophthalmic



wireless adaptive refractor visionfit adaptica - us ophthalmic

Benefits of the 2WIN
The 2Win may be integrated with the Vision Fit Adaptive Optics Refraction System to provide the most advanced mobile refraction process available today. This system is light, wireless, and easy to transport and set up for remote applications and screenings. The system can operate in very small areas (refracting distance as short as 1 meter) enabling unlimited flexibility for providing objective and subjective refractive exams.

Quick and objective measurement of binocular refraction.
Precise and objective measurements of ocular alignment.
Detection of the major amblyogenic factors such as anisometropia, anisocoria, media opacities, etc
Over-refraction with both spectacles and contact lenses
Objective measurement of dynamic pupilometry
Portable

wireless adaptive refractor visionfit adaptica - us ophthalmic

Applications of the 2WIN
Ophthalmic and Optometric Practices
Pediatric Eye Care
Orthoptics
Pediatricians
Vision Screening Programs
Mobile Eye Care
Occupational Medicine

wireless adaptive refractor visionfit adaptica - us ophthalmic

Practice Applications of the 2WIN
Rapid patient vision testing and screening
Refraction and Vision analysis of infants (0-3 year)
Vision care of disabled and/or un-cooperative patients
Analysis of binocular vision and accommodative balance
Early detection and documentation of multiple amblyogenic factors
Objective analysis of under- or over-corrections
Objective orthoptic exam

wireless adaptive refractor visionfit adaptica - us ophthalmic

Binocular / Monocular Refraction in a light controlled environment
When used with the Kaleidos module, the 2 Win can be used in a light controlled environment, eliminating distractions while fixing the distance for measurement. In this pairing, the instrument can be used for rapid walk-up screenings in any lighting conditions.



wireless adaptive refractor visionfit adaptica - us ophthalmic


VisionFit is an innovative electronic, tunable, all-in one, solid state, mobile and wearable system of lenses. It performs a subjective sight examination and it effectively replaces both the trial glasses and the manual/electronic phoropter functionality.

Wearable and mobile - it fits just like a trial frame
Adjustable step resolution down to 0.05 D
Enables examining in free posture
Small footprint and reduced exam time
Increases peripheral vision
Doesn’t require control of the patient’s position
Ideal with non-cooperative patients and handicap

wireless adaptive refractor visionfit adaptica - us ophthalmic
Wider Peripheral Vision
Due to the VisionFit’s slim and compact design, the peripheral vision is wider than any other phoropter available. This feature makes VisionFit the new concept for subjective refraction. By increasing the peripheral range this not only opens the door to a variety of new testing capabilities, but also allows the patient to have more confidence in the accuracy of their final prescription glasees.

Electronical Trial Frame
Adaptive Spherical Lens
Adaptive Cylindrical Lens
Add-On Lens Support

wireless adaptive refractor visionfit adaptica - us ophthalmic
Connectivity of the Mobile Wireless Refraction System (MWRS)
The VisionFit, being the top-of-the line subjective refraction system, utilizes Wifi and Bluetooth connection to synchronize with the 2WIN as well as the control panel. This wireless system also eliminates the problems caused by excess cords that may get in the way of the patient and operator.
The device can also be controlled remotely by the operator, which provides the most feasible and versatile option for diagnostic and service needs. Allowing the doctor to work at the comfort of his desk. Due to the fast and reliable wifi connection, the VisionFit can receive 2WIN objective Rx data which will minimize the examination process. The bluetooth functionality of the equipment makes it easier than ever to pair with any Android tablet. Standard cord connection is also available to the user.

wireless adaptive refractor visionfit adaptica - us ophthalmic
Portable and Rechargeable
The Mobile Wireless Refraction System composed of the 2WIN and the VisionFit travels in a conveniente combo carrying-case to serve all your outdoor eye-care activities (schools, nursing homes, etc).
The Mobile Wireless Refraction System allows the professional to accommodate his entire refraction practice in a single carry-on that can be taken immediately to practice everywhere. To ensure the portability and functionality of the Mobile Wireless Refraction System, equipped, with a rechargeable and replaceable battery pack. This battery pack provides a 2-3 day charge, which allows the doctor peace of mind that his equipment will be available to use when needed. The ability to use the device over and over without a charge is as incredible benefit for fast-paced ophthalmic clinics.
2WIN-4 Specifications
Operating Mode Binocular / Monocular
Refraction Measurement Automatic
Sphere Range +15, -15 D, step 0.25 D
Cylinder Range +5, -5 D, step 0.25 D
Cylinder Axis 1° – 180°, step 1°
Pupil Size Automatic Detection, 0.15-0.27in (4-7 mm), step 0.004in (0.1 mm)
Pupil Distance Automatic Detection, 1.18-4.72in (30-120 mm), step 0.04in (1 mm)
Fixation Target Built-in
Acoustic Target 1 m ± 5 cm
Data Interface Wi-Fi, USB, microSD card
Printer Interface USB, Infrared (irda)
Power Rechargeable Battery
Battery Charger 110-220 Vac, 0.5 A
Size 6.5 x 5.11 x 3.9 in (165 x 130 x 98 mm)
Display 3.5’’
Weight 1.85 lb (0.83 kg)
Options / Accessories Portable wireless printer, supplementary battery, battery-charger, metal case, Wi-Fi connectivity
VisionFit Specifications
Spherical Correction Range – 10/+10 D and -20/+20 D with the use of an additional lens with prescription steps of 0.125 D and variable fluidity steps (adjustable from 0.05 to 0.25 D) with the use of the basic spherical lens.
Cylindrical Correction Range 0 to 10 D by steps of 0.25 D
Axis Adjustament Range 1-180° by steps of 1°
Additional Prismatic Lenses Range (optional) 0 to 10 Δ, steps 1 Δ (add on – no automatic)
Corneal Vertex Distance Range 0.4-0.71in (10-18 mm)
Manual Pupil Distance Adjustment Range 2-3.15in (50-80 mm), separated right and left
Device Free Aperture 30 degrees
Display Android tablet 9.7″ multiple touch
Bluetooth Module BT 4.0 low energy
Power Rechargeable battery pack
Battery Charger AC-DC Medical Converter 24V 60W
2WIN-4 Specifications
Operating Mode Binocular / Monocular
Refraction Measurement Automatic
Sphere Range +15, -15 D, step 0.25 D
Cylinder Range +5, -5 D, step 0.25 D
Cylinder Axis 1° – 180°, step 1°
Pupil Size Automatic Detection, 0.15-0.27in (4-7 mm), step 0.004in (0.1 mm)
Pupil Distance Automatic Detection, 1.18-4.72in (30-120 mm), step 0.04in (1 mm)
Fixation Target Built-in
Acoustic Target 1 m ± 5 cm
Data Interface Wi-Fi, USB, microSD card
Printer Interface USB, Infrared (irda)
Power Rechargeable Battery
Battery Charger 110-220 Vac, 0.5 A
Size 6.5 x 5.11 x 3.9 in (165 x 130 x 98 mm)
Display 3.5’’
Weight 1.85 lb (0.83 kg)
Options / Accessories Portable wireless printer, supplementary battery, battery-charger, metal case, Wi-Fi connectivity
VisionFit Specifications
Spherical Correction Range – 10/+10 D and -20/+20 D with the use of an additional lens with prescription steps of 0.125 D and variable fluidity steps (adjustable from 0.05 to 0.25 D) with the use of the basic spherical lens.
Cylindrical Correction Range 0 to 10 D by steps of 0.25 D
Axis Adjustament Range 1-180° by steps of 1°
Additional Prismatic Lenses Range (optional) 0 to 10 Δ, steps 1 Δ (add on – no automatic)
Corneal Vertex Distance Range 0.4-0.71in (10-18 mm)
Manual Pupil Distance Adjustment Range 2-3.15in (50-80 mm), separated right and left
Device Free Aperture 30 degrees
Display Android tablet 9.7″ multiple touch
Bluetooth Module BT 4.0 low energy
Power Rechargeable battery pack
Battery Charger AC-DC Medical Converter 24V 60W

Recently viewed