CASIA2 de Tomey es una solución de diagnóstico por imagen de segmento anterior de alta precisión, diseñada para aplicaciones avanzadas en cirugía de catarata, glaucoma y córnea. Con un análisis de ángulo de 360° para glaucoma, escaneo de alta velocidad (50,000 A-scans/segundo) y una profundidad de escaneo de hasta 13 mm, el CASIA2 ofrece imágenes detalladas y de alta resolución. Entre sus funciones destacan la topografía corneal, simulación de IOL fáquicas, análisis de forma del cristalino, cálculos para selección de lentes intraoculares, y herramientas completas para evaluaciones pre y postoperatorias, incluyendo ICL. Todo esto lo convierte en una herramienta integral para una evaluación clínica completa y precisa.

CATARACT

oct casia2 tomey - us ophthalmic
Cataract Application

The Pre-OP Cataract application guides you through ideal preparation for cataract surgery by displaying essential screening parameters for IOL selection. The Post-OP application clearly visualizes and documents surgical quality, providing deeper insight into outcomes. The new color camera improves toric IOL alignment checks by displaying toric markers in various modes. Additionally, a new scan type (IOLSCAN) has been added to the Post-OP Cataract application, offering enhanced visualization of the IOL.

oct casia2 tomey - us ophthalmic
Total Analysis

Anterior segment images and parameters for both eyes can be reviewed at a glance. In addition to conventional pre- and post-op exams, CASIA2 supports routine clinical operations such as initial exams, follow-ups, and informed consent discussions. Parameters are color-coded to highlight differences between left and right eyes or when values fall outside standard ranges.

oct casia2 tomey - us ophthalmic
Lens Analysis

The unique Lens Analysis application provides you with all relevant lens parameters, including front and back radial curvature and the lens tilt and decentration. With this tool a precise prediction of your surgery result is guaranteed.

Pre-OP ICL

Featuring two built-in sizing recommendation formulas, this application helps confirm appropriate ICL sizing for surgery.

oct casia2 tomey - us ophthalmic
Post-op Application

The Post-op application clearly visualises and documents the quality of your cataract surgery with all needed information for your ideal check-up.

GLAUCOMA

oct casia2 tomey - us ophthalmic
STAR 360° & Glaucoma Application

With our STAR 360° application the CASIA2 automatically measures the anterior chamber angles all around the anterior segment due to its automatic scleral spur detection and provides you with all detailed parameters for a ideal glaucoma diagnosis.

oct casia2 tomey - us ophthalmic

It does not only measure but also display the result in a very detailed and unrivalled chart. The charts can be chosen upon your needs out of all measured values.

oct casia2 tomey - us ophthalmic

All regions of your interest, no matter how small and in which peripheral area can be scanned also with a raster scan method, which leads to a fantastic scanning density with a high resolution.

CORNEA

oct casia2 tomey - us ophthalmic
Corneal Application

A topographic image is taken in only 0.3 seconds, which guarantees no artefacts at all. The cornea can be displayed in different map types in a wide range of individual settings, either in 10 mm or 16 mm diameter. Scleral lens fitting is no problem anymore.

oct casia2 tomey - us ophthalmic
Trend Analysis Application

Our unique Trend Analysis application visualises the chronological progress of the post treatment regression of the eye, which allows you a very good follow-up. Different parameters can be chosen for this chart.

MEASUREMENT RESOLUTION
Axial (Depth) 10 µm or Ѵess (in tissue)
Transverse 30 µm or Ѵess (in air)
MEASUREMENT SCAN RANGE
Depth 13 mm
Transverse Radial scan: Ø 16 mm
Raster scan: 12 × 12 mm
MAIN UNIT
Scan Rate 50,000 A-scans/second
Stroke range of moving section 40 mm (y-axis); 88 mm (x-axis); 43 mm (z-axis)
Stroke range of chin rest 70 mm
Type of light source Swept Laser Source
Laser source wavelength 1,310 nm
WORKSTATION COMPUTER
External HDD 8 TB or more
OS Windows®10 64 bi
CPU Intel® Core i5
Memory 8 GB or more
SSD 128 GB
HDD 8 TB or more
Data Output Printer (LAN,USB)
Display Touch panel LCD monitor 20" or larger
DIMENSIONS AND ELECTRICAL REQUERIMENTS
Dimensions WDH 530 x 560 x 455 mm
Weight approx. 33 kg
Voltage 100 VAC to 240 VAC
Frequency 50 / 60 Hz
Power Comsumption 170 VA
Power Output Less than 6 MW
Laser Class Class 1