slit lamp sl-1400 luxvision - us ophthalmic

Versatile Optic System
This Galilean microscope with stereoscopic head simplifies and brings clarity to even the most challenging examinations. The optics in the SL-1400 Slit Lamp are ideal for technologically advanced imaging systems. An optional beamsplitter will allow you to illustrate pathology using digital and video imaging systems when these tools are in position. The dual port beamsplitter also allows an assistantscope to be attached.

slit lamp sl-1400 luxvision - us ophthalmic

Magnification Selection Dial
Luxvision’s SL-1400 Slit Lamp gives you the power to select from five steps of magnification—from 6x up to 40x—simply by twisting a single knob. Changing an eyepiece is not required. Using the conveniently located knob, operators can choose from total magnification ratios equivalent to 6x (Ø33mm), 10x (Ø22.5mm), 16x (Ø14mm), 25x (Ø8.8mm), 40 (Ø5.5mm). Fine adjustments can also be made to the PD and optical correction.

slit lamp sl-1400 luxvision - us ophthalmic

Two Fixation Target Options
The SL-1400 offers two options with respect to fixation targets. One is for diopter adjustment to help the patient to see the target clearly while the other is an illuminated fixed spot. The fixation target with diopter compensation supplies a dot and concentric circles target. Operators simply slide the knob to adjust the diopter compensation within the range from -15D to +10D. The fixation target with spot light is especially well suited to patients with refractive errors exceeding -15D.

slit lamp sl-1400 luxvision - us ophthalmic
Wide Field of View with a Range of PD and Diopter Adjustment
Luxvision’s SL-1400 Galilean optical system delivers an exceptionally wide field of view of Ø33mm, Ø22.5mm, Ø14mm, Ø8.8mm, and Ø5.5mm, with a 55mm-75mm range of PD adjustment and -5D to +3D diopter adjustment.

slit lamp sl-1400 luxvision - us ophthalmic


High Clarity Luminance and Built-in Filters
The SL-1400 utilizes a 12-volt, 30-watt high luminance halogen bulb to provide bright illumination and outstanding clarity. By shifting the unit’s filter selection lever, you can easily select from four built-in Illumination Pathway Filters. Options include a heat absorption filter that aids in patient comfort during lengthy exams, a red-free filter that enhances structural contrast, a cobalt blue filter for use in fluorescein assessment, and a grey filter. When indirect retro-illumination is needed, you can easily deflect the illumination light using the unit’s well-placed controls. In addition, the SL-1400 features a diffusion lens for enlarging the illumination field as well as for observation and photography at low magnificat.

slit lamp sl-1400 luxvision - us ophthalmic


Continuous Slit Rotation and Aperture Adjustment
The SL-1400 features 2/3x slit projection magnification and enables users to modify slit width continuously from 0mm to 9mm using an easy-to-adjust knob. The slit becomes a circle at 9mm. A helpful scale on the knob indicates the width value. The seven available aperture diameters are Ø9mm, Ø8mm, Ø5mm, Ø3mm, Ø2mm, Ø1mm, and Ø0.2mm. The slit height, which is indicated in a display window, also can be changed continuously, from 1mm to 8mm. Using precise movements and controls, operators can swing the main body of the slit horizontally to revolve the slit image at any angle in the vertical or horizontal direction, from 0° to 180°. Another helpful scale indicated the angle of image rotation. Four steps of slit inclination—5°, 10°, 15°, 20° — also are available for oblique illumination in contact lens evaluations.

. Another helpful scale indicated the angle of image rotation. Four steps of slit inclination—5°, 10°, 15°, 20° — also are available for oblique illumination in contact lens evaluations.



slit lamp sl-1400 luxvision - us ophthalmic


Integrated Multidirectional Joystick
Maneuver the SL-1400 with ease using the intuitive multidirectional joystick. Precision adjustments are at your fingertips by simply turning and tilting the joystick. The base operation of the SL-1400 offers the following movements: forward and back movement to 90mm; left and right movement to 100mm, fine movement to15mm and vertical movement to 30mm. Once you achieve the proper alignment, the base can be locked to prevent sliding.

slit lamp sl-1400 luxvision - us ophthalmic

Fundus Observation
Unlike standard slit lamp units, Luxvision’s SL-1400 also allows for a dilated examination of the fundus and the posterior segment of the vitreous body using a Hruby Lens with the unit’s Hruby Lens Holder and Hruby Lens Guide Plate.

slit lamp sl-1400 luxvision - us ophthalmic

Tonometry and Other Accessories
Luxvision’s SL-1400 slit lamp can be equipped with the TN-150 / TN-150B applanation tonometer or the Haag-Streit AG Model R-900 or Model T-900 applanation tonometer for measuring intraocular pressure. The unit’s accessories mount also allows you to attach other accessories, including photography and video accessories. In addition, you can replace the standard eyepieces with 12.5x measuring eyepieces that include reticules for measurement of length and angle.
Microscope
Type Galileo, magnification changer with stereoscopic head
Magnification 5 steps via ring rotation
Eyepiece 12.5x
Total Magnification Rate
6x, 10x, 16x, 25x, 40x
Field of View (ø1.3in / 33mm) (ø0.9in / 22.5mm) (ø0.55in / 14mm) (ø0.3in / 8mm) (ø0.3in / 5.5mm)
Range of P.D. Adjustment 2.16in to 3in (55mm to 75mm)
Diopter Adjustment -5D to +3D
Illumination
Slit Projection Magnification 2/3x
Slit Width Continuous from 0mm to 9mm
(at 0.35in / 9mm, slit becomes a circle)
Slit Height Continuous from 1mm to 8mm
Aperture Diameter ø0.35in / 9mm, ø0.31in / 8mm, ø0.2in / 5mm, ø0.12in / 3mm, ø0.08in / 2mm, ø0.04in / 1mm, ø0.008in / 0.2mm
Slit Angle 0º to 180º continuously adjustable from vertical to horizontal
Slit Inclination 5º, 10º, 15º, 20º four steps
Filter Piece Heat-absorption, Grey, Red-Free and Blue
Illumination Bulb 12V30W halogen bulb
Movement Base
Fore and Back Movement 3.54in / 90mm
Left and Right Movement 3.94in / 100mm
Fine Movement 0.6in / 15mm
Vertical Movement 1.18in / 30mm
Chin-Rest Parts
Vertical Movement 3.15in / 80mm
Fixation Target Red LED
Hurby Lens
Hurby Lens -58.7D (optionally available in some regions)
Power Source
Input Voltage 100/220V ~ ±10%
Input Frequency 50/60 Hz ± 1Hz
Input Power 58VA
Output Voltage Illumination bulb 7.2V, 9.8V, 11.6V
Fixation target 7.2V
Electric Safe Standard Conform to Standard IEC601 - 1, Class I Type B
Dimension and Weight
Packing Box 28.35 x 19.5 x 18.9in (720 x 495 x 480mm)
Total Weight 52.8lb / 24 Kg
Net Weight 46.2lb / 21 Kg
Microscope
Type Galileo, magnification changer with stereoscopic head
Magnification 5 steps via ring rotation
Eyepiece 12.5x
Total Magnification Rate
6x, 10x, 16x, 25x, 40x
Field of View (ø1.3in / 33mm) (ø0.9in / 22.5mm) (ø0.55in / 14mm) (ø0.3in / 8mm) (ø0.3in / 5.5mm)
Range of P.D. Adjustment 2.16in to 3in (55mm to 75mm)
Diopter Adjustment -5D to +3D
Illumination
Slit Projection Magnification 2/3x
Slit Width Continuous from 0mm to 9mm
(at 0.35in / 9mm, slit becomes a circle)
Slit Height Continuous from 1mm to 8mm
Aperture Diameter ø0.35in / 9mm, ø0.31in / 8mm, ø0.2in / 5mm, ø0.12in / 3mm, ø0.08in / 2mm, ø0.04in / 1mm, ø0.008in / 0.2mm
Slit Angle 0º to 180º continuously adjustable from vertical to horizontal
Slit Inclination 5º, 10º, 15º, 20º four steps
Filter Piece Heat-absorption, Grey, Red-Free and Blue
Illumination Bulb 12V30W halogen bulb
Movement Base
Fore and Back Movement 3.54in / 90mm
Left and Right Movement 3.94in / 100mm
Fine Movement 0.6in / 15mm
Vertical Movement 1.18in / 30mm
Chin-Rest Parts
Vertical Movement 3.15in / 80mm
Fixation Target Red LED
Hurby Lens
Hurby Lens -58.7D (optionally available in some regions)
Power Source
Input Voltage 100/220V ~ ±10%
Input Frequency 50/60 Hz ± 1Hz
Input Power 58VA
Output Voltage Illumination bulb 7.2V, 9.8V, 11.6V
Fixation target 7.2V
Electric Safe Standard Conform to Standard IEC601 - 1, Class I Type B
Dimension and Weight
Packing Box 28.35 x 19.5 x 18.9in (720 x 495 x 480mm)
Total Weight 52.8lb / 24 Kg
Net Weight 46.2lb / 21 Kg