HIS-5000 5X - US Ophthalmic
HIS-5000 5X - US Ophthalmic
HIS-5000 5X - US Ophthalmic
HIS-5000 5X - US Ophthalmic
HIS-5000 5X - US Ophthalmic
HIS-5000 5X - US Ophthalmic
HIS-5000 5X - US Ophthalmic
Load image into Gallery viewer, HIS-5000 5X - US Ophthalmic
Load image into Gallery viewer, HIS-5000 5X - US Ophthalmic
Load image into Gallery viewer, HIS-5000 5X - US Ophthalmic
Load image into Gallery viewer, HIS-5000 5X - US Ophthalmic
Load image into Gallery viewer, HIS-5000 5X - US Ophthalmic
Load image into Gallery viewer, HIS-5000 5X - US Ophthalmic
Load image into Gallery viewer, HIS-5000 5X - US Ophthalmic
10 visitors are looking this product!

"See the difference..."
Intuitive and user-friendly information management and processing.


slit lamp his-5000 10M

Illumination system brings extremely bright and vivid vision
This Haag-Streit Style Tower Illumination slit lamp uses a 12-volt, 30-watt high luminance halogen lamp to provide the purest possible image.

slit lamp his-5000 10M

Magnification Control System that can be used in various observations
The uniquely designed Huvitz optic system eliminates image distortion at all magnification levels, enabling you to achieve a more precise diagnosis. The unit’s five-position drum-style magnification changer provides easy access to magnification levels ranging from 6x to 40x.

slit lamp his-5000 10M

A Faster, More Stable Digital Camera
The HIS-5000 5X 10M offers high resolution imaging of 10 M pixels using an IEEE 1394 interface method, which conducts image data transfer faster and with more stability compared to the normal USB interface method.

slit lamp his-5000 10M

Easy to Use Microscope
The HIS-5000 5X 10M features a Galilean Converging Binocular optical system that delivers vivid images and a wide field of view. Operators can select from total magnification ratios equivalent to 6x (∅38.5mm), 10x (∅22.2mm), 16x (∅15.2mm), 25x (∅10.5mm), and 40x (∅6.7mm).

slit lamp his-5000 10M

Integrated Control
The omnidirectional style joystick is simple to control. An integrated trigger button allows for convenient image and video capture. When the slit lamp is connected to imaging devices, images and videos can be stored simultaneously.

Slit Lamp HIS-5000 5X 10M Huvitz

Ergonomicaly Designed Illumination Control
The illumination lever is conveniently located next to the joystick. The brightness control switch can be set to High or Normal, making diagnostic procedures even easier.

slit lamp his-5000 10M

Five Filters, Including Yellow
Five built-in Illumination Pathway Filters can be effortlessly inserted into the illumination pathway using the selection lever. Options include a heat absorption filter that aids in patient comfort during lengthy exams, a red-free filter that enhances structural contrast, a cobalt blue filter for use in fluorescein assessment, a grey filter, and a yellow filter to absorb blue light and enhance contrast.

Available with LED or Halogen Light Source
This slit lamp is now offered in your choice of LED or Halogen. LED illumination source technology offers a sharper, brighter and most homogeneous slit than conventional lighting. The shorter wavelength of the LED spectrum light ensures that you’ll see all structures with better detail. LED also provides cost and energy savings—you’ll enjoy a substantial reduction in bulb replacement.


User-Friendly Patient Information Management
MS Access Database designed system allows you to search and easily manage previous and current data for all of your patients.


slit lamp his-5000 10M

Intuitive Interface
A tree-structured user interface helps users access information quickly, without any complicated multi-step clicking.

Real Time Quick Image Capture
The high performance progressive scan CCD camera displays captured images in real time.


slit lamp his-5000 10M

Powerful Image Processing
The HIS-5000 5X 10M supports JPG, TIFF, RAW and many more image formats. Operators can access them in the unit’s Live Tool graphic library, and then adjust them at will for brightness, contrast, color channel, saturation, inversion, sharpness, red-free, etc.

Diagnose, Reference, Report and Share


slit lamp his-5000 10M

[Compare]
Users can apply various effects to images. For instance, selected images can be magnified, reduced and rotated for accurate comparison and diagnosis.

slit lamp his-5000 10M

[Overlay]
The ability to compare images captured at different time frames allows you to detect progression.

slit lamp his-5000 10M

[Slide Show]
All images can be selected for use in presentations and slide shows.

slit lamp his-5000 10M

[Reference]
Easily locate multiple images of the same finding for further reference.

slit lamp his-5000 10M

[Report Generation]
Automatically export patient reports in MS Words format.

[Print]
Easy single-click printing of images.


Price does not include Computer shown in Images. Item only contains: Slit Lamp, Camera, Fiber optics for background Illumination and Software.

Slit Illumination
Slit Length(mm) 0.3~14
Slit Width (mm) 0~14 continuous
Slit Projection 1x
Aperture Diaphragms 0.02 / 0.04 / 0.11 / 0.19 / 0.4 / 0.47in (0.3 / 1 / 3 / 5 / 9 / 12mm)
Filters Cobalt Blue, Red-Free, Yellow, Grey and Heat Absorbing
Slit Rotation 0°~180°continuous
Light Source Option of LED or Halogen Lamp
Patient's Eye / Prism
Angle of Incidence 0°, 5°, 10°, 15°, 20°
Surface Working Distance 3.14in (80mm)
Microscope
Microscope 5 steps
Type Galilean Converging Binocular
Magnification 5 Position Rotating Drum
Eyepieces 12.5x
Total Magnifications 6x, 10x, 16x, 25x, 40x
Real Fields of View (mm) 38.5, 22.2, 15.2, 10.5, 6.7
Inter-pupilary Adjustment 2.16in~3.14in (55mm~80mm)
Base
Vertical Movement 1.10in (28mm)
Longitudinal Movement 3.07in (78mm)
Lateral Movement 3.85in (98mm)
Fine Base 0.4in (10mm)
Power Supply Free Voltage 100~240V AC
Voltage Frequency 50/60Hz
Power Consumption 70VA
Instrument Voltage 12V DC
Halogen Bulb 12V 30W
Fixation Point Bulb 3.4V 20mA
Digital Camera
Image Sensor 1/2"" CMOS
Image Size up to 3840 x 2748 pixels
Cell Size 1.67 µm x 1.67 µm
Transmit Method USB 2.0
Transmit Speed 480Mbps
Frame Rate Maximum 30fps
Lens Mount C-Mount
Power Consumption 2.5W
 
CPU Pentium IV, 2GHz
Memory 512 MB (Over 1 GB recommended)
Video Card ATI Radeon 9200 (128MB) or similar
System Microsoft Windows NT (with service pack 6), Windows 2000 (with service pack 4)
Transmit Method Windows XP, Microsoft Internet Explorer 6 (Explorer 7 recommended)
Standard IEEE 1394a Firewire port OHCI 1.1 compatible (with auxiliary 12V power connector if connected to a laptop computer)
Monitor Monitor: LCD or CRT (minimum resolution 1,280x1,024 pixels, over 1,600x1,200 pixels recommended)
OPTION: PC, Table Designs and details may be changed without prior notice for the purposes of improvement
Slit Illumination
Slit Length(mm) 0.3~14
Slit Width (mm) 0~14 continuous
Slit Projection 1x
Aperture Diaphragms 0.02 / 0.04 / 0.11 / 0.19 / 0.4 / 0.47in (0.3 / 1 / 3 / 5 / 9 / 12mm)
Filters Cobalt Blue, Red-Free, Yellow, Grey and Heat Absorbing
Slit Rotation 0°~180°continuous
Light Source Option of LED or Halogen Lamp
Patient's Eye / Prism
Angle of Incidence 0°, 5°, 10°, 15°, 20°
Surface Working Distance 3.14in (80mm)
Microscope
Microscope 5 steps
Type Galilean Converging Binocular
Magnification 5 Position Rotating Drum
Eyepieces 12.5x
Total Magnifications 6x, 10x, 16x, 25x, 40x
Real Fields of View (mm) 38.5, 22.2, 15.2, 10.5, 6.7
Inter-pupilary Adjustment 2.16in~3.14in (55mm~80mm)
Base
Vertical Movement 1.10in (28mm)
Longitudinal Movement 3.07in (78mm)
Lateral Movement 3.85in (98mm)
Fine Base 0.4in (10mm)
Power Supply Free Voltage 100~240V AC
Voltage Frequency 50/60Hz
Power Consumption 70VA
Instrument Voltage 12V DC
Halogen Bulb 12V 30W
Fixation Point Bulb 3.4V 20mA
Digital Camera
Image Sensor 1/2" CMOS
Image Size up to 3840 x 2748 pixels
Cell Size 1.67 µm x 1.67 µm
Transmit Method USB 2.0
Transmit Speed 480Mbps
Frame Rate Maximum 30fps
Lens Mount C-Mount
Power Consumption 2.5W
 
CPU Pentium IV, 2GHz
Memory 512 MB (Over 1 GB recommended)
Video Card ATI Radeon 9200 (128MB) or similar
System Microsoft Windows NT (with service pack 6), Windows 2000 (with service pack 4)
Transmit Method Windows XP, Microsoft Internet Explorer 6 (Explorer 7 recommended)
Standard IEEE 1394a Firewire port OHCI 1.1 compatible (with auxiliary 12V power connector if connected to a laptop computer)
Monitor Monitor: LCD or CRT (minimum resolution 1,280x1,024 pixels, over 1,600x1,200 pixels recommended)
OPTION: PC, Table Designs and details may be changed without prior notice for the purposes of improvement