Ezer Wall Unit Transformer EZ-WOT-1800 DC

REQUEST QUOTEor call toll-free (888) 881-1122Financing available — simple terms, no leasing. Ask about it in your quote request.

Ezer Diagnostic Wall Unit, with C battery dispenser and AC power supply, is designed for disease diagnosis

Ezer EZ-WOT-1800 DC Wall Unit Transformer

Complete integrated wall-mounted diagnostic unit

All-in-one system including an ophthalmoscope and otoscope with interchangeable heads. Ideal for practices requiring both ophthalmic and otorhinolaryngological diagnosis in a single unit.

Ophthalmoscope with 19 precision lenses

Dioptric range from 0D to ±20D with multiple apertures and red-free filter. Specifically designed for small pupil examination and detailed fundus exploration.

Advanced fiber optic LED technology

Fiber optic light transmission system that reaches the tip of the instrument. Provides greater illumination with minimal glare for accurate diagnostics.

Dual feed with dispenser included

Operates on C batteries and AC power for maximum versatility. Includes a built-in dispenser integrated into the wall unit to keep the equipment organized and ready for use at all times.

Ezer EZ-WOT-1800 DC Wall Unit Transformer
Ezer EZ-WOT-1800 DC Wall Unit Transformer

Includes 1 Ophthalmoscope head, 1 Otoscope head, C battery and AC power supply.

Ophthalmoscope

The direct ophthalmoscope is used to examine the internal structures of the eye and its fundus.

▪ Available with alkaline AA or Ni-MH batteries. Bulb power: 2.5V, 1.6W.
▪ Smart design and comfortable operation
▪ Suitable for small pupils
▪ 19 lenses from 0D to ±20D: 0D, ±1D, ±2D, ±3D, ±4D, ±6D, ±8D, ±10D, ±15D, ±20D.
▪ Use only with LED bulb

Red-free filter, semicircle, small spot, large spot, fixation aperture.

Ezer Wall Unit Transformer EZ-WOT-1800 DC – image 1

Otoscope

The otoscope is used to observe the tympanic membrane and the external auditory canal in order to diagnose pathologies of the outer and middle ear. It is the most widely used device in otolaryngology. The fiber optic light transmission system extends the fiber to the tip of the instrument, providing greater light output and reduced glare.

▪ 2.5x magnification
▪ Reusable ear specula: 2.5 mm and 4.0 mm, 5 of each. 3 mm and 5 mm optional.
▪ Insufflation port: allows observation of the tympanic membrane using an insufflation bulb.
▪ Smart design, comfortable for mobile diagnostics.
▪ Use only with LED bulb

Specifications

Ezer Wall Unit Transformer EZ-WOT-1800 DC specifications
Ophthalmoscope
Optical Specifications
19 assorted lenses with powers ranging from 0D to ±20D 0D, ±1D, ±2D, ±3D, ±4D, ±6D, ±8D, ±10D, ±15D, ±20D
Opening Red-free filter Large spot Small spot Hemi-spot Fixation aperture
Electrical Specification
Nominal Voltage Two AA alkaline or Ni-MH batteries
Bulb type 2.5 V / 1.6 W
Electrical Safety Standard Complies with EN60601-1 / EN60601-1-2 Protection: Internal electrical power supply Operating mode: Intermittent. 2 minutes 'ON'. 5 minutes 'OFF'
Environmental Requirements
Operation
Ambient Temperature +10 °C - +35 °C
Relative Humidity 30% - 75%
Atmospheric Pressure 700 hPa - 1060 hPa
Shipping Common Shipping
Storage
Temperature -40 °C - +55 °C
Relative humidity 10% - 90%
Air Pressure 500 hPa - 1060 hPa
Otoscope
Optical Specifications
Illumination Fiber optic transmits light
Lens magnification 2.5 x
Specifications of the ear specula
Diameter of the ear specula 0.10in/2.5mm, 0.16in/4mm
Insufflation Port Specifications
Insufflation Port Yes
Electrical Specification
Bulb 2.5V / 1.6W
Nominal Voltage Two AA alkaline or Ni-MH batteries
Operating Mode Intermittent: on-time must not exceed 2 min with off-time no less than 5 min
Electrical Safety Complies with EN60601-1 / EN60601-1-2 Protection: Internal electrical power supply Applied part type BF
Environmental Requirements
Operation
Ambient Temperature +10 °C - +35 °C
Relative Humidity 30% - 75%
Atmospheric Pressure 700 hPa - 1060 hPa
Shipping Common Shipping
Storage
Temperature -40 °C - +55 °C
Relative Humidity 10% - 90%
Air Pressure 500 hPa - 1060 hPa