The Ezer EDR-H Digital Refractor has been redesigned for a smaller, slimmer form factor. The placement of touch buttons combined with the touchscreen interface makes the EDR-H easy to use. Boost your efficiency with features such as dual cross-cylinder testing, programmable examination sequences, and wireless connectivity with other preliminary testing equipment. The Ezer EDR-H Digital Refractor brings cutting-edge technology, modern design, and precision optics to the examination room, making ophthalmic exams straightforward.
Dual Cross Cylinder Lens
A new and improved method for refining the cylinder axis and power using the Dual Cross Cylinder Lens. This allows the patient to view a split/dual image of the test object so they can easily discern which image is more visually appealing. This feature reduces patient confusion and accelerates the refraction process. The cross cylinder examination is more accurate and effective for astigmatism tests, as the doctor can adjust the incremental axis change for higher cylindrical powers. The spherical equivalent can also be adjusted automatically.

Ergonomic Design
Measuring the refractive index and spectacle prescription of a patient is painless with the EDR-H. The EDR-H is designed to perform all types of astigmatism tests, spherical refinement, binocular vision assessments, and more. The carefully crafted lenses within this digital refractor provide a wide dioptric range (-29D to +26.75D), delivering accurate measurements regardless of the severity of myopia. Thanks to the wide 40-degree field of view, test results can be reliably ensured with precision.

Advanced Engineering
The stepper motors operate at high speeds, ensuring that the lenses are correctly positioned for the patient, reducing patient confusion and significantly accelerating the examination process. Thanks to Ezer’s engineering expertise, all adjustments that must be performed by the refractor during and between tests are handled by the silent internal mechanisms of the headset.

Optometric Charts and Tests
The EDR-H offers globally standardized optometric charts. With an integrated System Program, Custom Programs, and Unit Test Functions, the possibilities are endless. Professionals can fully control the examination according to their own professional preferences.

Near Vision Chart
The Visual Test function makes it easier to help patients understand the differences between various refractive errors and diseases. Near visual acuity testing can be performed with the near vision chart and the auxiliary eye chart. These eye charts can be selected according to user preferences and testing objectives.

Closed Optical System
The EDR-H has been designed with a closed optical system. This minimizes the chances of the patient’s ocular fluids contaminating the internal lenses.
Forehead Sensor
The forehead position detector is equipped with alert functions to indicate the optimal facial position for each patient during testing. This system can also verify that patients maintain a correct postural position throughout each test.

Large and Convenient Touchscreen Display
Most of the interface is controlled through the touchscreen, with only a few physical buttons on the base of the unit to manage the most essential functions. As the diagnosis progresses, figures are displayed on a wide 10.4-inch screen with an intuitive, multi-color interface. The screen layout is easy to understand, keeping the practitioner informed of the test content at all times. By adopting a touchscreen interface, optometrists can take advantage of the most advanced technology, even if they are not fully familiar with this progressive technology.

Provides an Independent Tiltable and Rotatable Monitor
Regardless of the patient’s or optometrist’s position, the screen can be rotated to any angle or direction.

A wide central dial allows users to change measurement values with a pleasant tactile feel reminiscent of manual instruments, enhancing the user experience. The click function provides lens conversions and program executions in a much faster and more convenient manner. The new and improved key design is organized by function and features excellent tactile sensitivity and increased durability.

Integrated Printer
All examination data is automatically stored in the control box and can be quickly retrieved by the user at any time. The control box also features an integrated printer to easily produce a hard copy of test results on demand. Additionally, the control box comes preloaded with several easy-to-understand patient education slides: simply tilt and rotate the screen toward the patient to engage them in their eye care.

Compatible Multi-System Connection
The EDR-H can be connected to several other Ezer digital ophthalmic instruments to serve as the hub of a digitally enabled examination room. Data can be entered or transferred directly from compatible devices, and the control box can operate many of the different functions of each device.

Wireless connection (optional)
EDR-BH can be connected to ERK-BH, EDC-BH and ELM-BH via WIFI.

DIGITAL CLINIC

What is an EMR?
Electronic Medical Records, commonly abbreviated as “EMR”, are a technological tool widely used in modern medical practices. EMR systems were designed to replace obsolete paper-based record-keeping methods and to optimize the collection and tracking of patient data over time. EMR platforms integrate the various components of a medical office visit, including admission demographic data and clinical history, prescription information, laboratory data, practice management software, examination notes, and more. In general, EMR systems are used to promote economic efficiency and improve patient care through seamless coordination of data collection and storage. EMR platforms also increase patient transparency through the use of portals where patients can view important results and communicate securely with physicians.
In the ophthalmic industry, EMR systems are more important and popular than ever. The ability to store critical laboratory data related to prescriptions and diagnoses while maintaining quick access to that information is key to reducing chair time and improving patient outcomes and satisfaction. With Ezer Digital Practice, sharing information is easier than ever! The ELM-BH Lensometer, the ERK-H/BH Autorefractor, the EDR-H Phoropter, and the EDC-BH Visual Acuity Chart interact via Wi-Fi to streamline communication between your preliminary testing and examination rooms.

We know it can be intimidating to introduce new technology into your practice, but with Ezer Digital Practice equipment and the superior technical support of US Ophthalmic, your practice will save time and money with seamless EMR integration.
Our EMR Partners
| Our EMR Partners | ![]() |
![]() |
Simple Maintenance and Updates
The front pedestal, facial contact piece, and eyepiece protective lens are designed to be removable, allowing for easy removal and cleaning. This enables professionals to maintain a hygienic testing environment. Additionally, the system software can be easily updated via the USB interface. EDR-H provides ophthalmology practices with a unified experience and a seamless data platform. This instrument will bring a new level of synergy to your practice, equally benefiting patients, physicians, and technicians.
Specifications
| Spherical Power (SPH) | |
|---|---|
| Measurement Range | -29.00 ~ +26.75D (general) -19.00 ~ +16.75D (cross cylinder or prism) |
| Measurement Unit | 0.12D/0.25D/0.50D/1.00D |
| Cylindrical Power (CYL) | |
| Measurement Range | 0D ~ ±8.75D |
| Measurement Unit | 0.25D/1D/2D/3D |
| Axis (AX) | |
| Measurement Range | 0°~180° |
| Measurement Unit | 1°/5°/15° |
| Interpupillary Distance | |
| Measurement Range | 1.9 ~ 3.15in, measurement distance, 13.8 ~ 27.6 (48 ~ 80mm, measurement distance, 350 ~ 700mm) |
| Measurement Unit | 0.02/0.04in (0.5mm/1mm) |
| Prism Degree | |
| Measurement Range | 0△~20△ |
| Measurement Unit | 0.1△/0.5△/2△ |
| Prism Angle | |
| Measurement Range | 0°~360° |
| Measurement Unit | 1°/5° |
| Cross Cylinder | Automatic Cross Cylinder (±0.25D) 0.25D ± cross cylinder 0.50D ± cross cylinder |
| Auxiliary Lens | P.D/cover/pinhole(? 2mm)/polarized light filter(45°/135°) maddox rod(right eye: horizontal, left eye: vertical) red-green filter(right eye: red filter, left eye: green filter) polarized light filter(right eye: 135°, 45°)(left eye: 45°, 135°) dissociation prism(right eye: 6△BU, left eye: 10△BU) |
| Size | Refractor: 12.8-15.3(W)x9.6(D)x2.32(H)in/8.14lb (323-389(W)x245(D)x59(H)mm/ 3.7kg) Controller: 10.23(W)x9.05(D)x2.3(H)in/6.82lb (printer included) (260(W)x230(D)x58(H)mm/ 3.1kg(printer included)) Junction Box: 8.3(W)x7.5(D)x2.8(H)in/ 4.62lb(printer included) (210(W)x190(D)x70(H)mm/ 2,1kg(printer included)) |