Visionare Refraction Unit Portofino

REQUEST QUOTEor call toll-free (888) 881-1122Financing available — simple terms, no leasing. Ask about it in your quote request.

The Portofino Refraction Unit is equipped with multiple fully motorized systems and precision-manufactured components that work together to prioritize user comfort. The Portofino Refraction Unit achieves the perfect balance between versatility, quality craftsmanship, and comfort, making it the ideal refraction unit for any ophthalmology clinic.

Visionare Refraction Unit Portofino

Fully Motorized Systems

Multiple motorized systems work together for smooth and precise operation.

High-Precision Manufacturing

Precision-manufactured components ensure reliable results in every refraction examination.

Maximum User Comfort

Design focused on prioritizing the comfort of both the patient and the professional during the examination.

Versatility for Any Clinic

Perfect balance between versatility and quality, making it ideal for any ophthalmological setting.

Visionare Refraction Unit Portofino – image 9
Visionare Refraction Unit Portofino – image 10
Visionare Refraction Unit Portofino
Visionare Refraction Unit Portofino – image 12
Visionare Refraction Unit Portofino – image 13
Visionare Refraction Unit Portofino – image 14
Visionare Refraction Unit Portofino – image 15
Visionare Refraction Unit Portofino – image 16
Visionare Refraction Unit Portofino – image 17
Visionare Refraction Unit Portofino – image 18
Visionare Refraction Unit Portofino – image 19
Visionare Refraction Unit Portofino – image 20
Visionare Refraction Unit Portofino – image 21
Visionare Refraction Unit Portofino – image 22
Visionare Refraction Unit Portofino – image 23
Visionare Refraction Unit Portofino – image 24
Visionare Refraction Unit Portofino – image 25
Visionare Refraction Unit Portofino – image 26
Visionare Refraction Unit Portofino – image 27
Visionare Refraction Unit Portofino – image 28
Visionare Refraction Unit Portofino – image 29
Visionare Refraction Unit Portofino – image 30
Visionare Refraction Unit Portofino – image 31
Visionare Refraction Unit Portofino – image 32

Hosts three instruments on the table

The specialists can customize the Portofino table with up to three different devices, keeping unsightly cables and cords out of the patient’s view.

Visionare Refraction Unit Portofino – image 1

Flexibility with multidimensional movement

The table offers flexibility with multidimensional movement. It can be adjusted vertically and rotated, adapting to both the patient and the specialist. This flexibility in the table’s movement keeps the patient comfortable and reduces repetitive strain on the specialist.

Visionare Refraction Unit Portofino – image 2

Lift Boy System

Best of all, there is no need to meticulously realign the equipment every time an adjustment is made, thanks to the innovative mechanics of the Lift Boy system. The specialist can calibrate the Lift Boy to compensate for the height difference between two pieces of equipment used simultaneously. Once the table has been programmed, the physician can switch between instruments and the table will automatically rise or lower to the correct working height. These features prevent physicians from having to repeatedly adjust the table and chair when changing equipment. Valuable time is saved for both the physician and the patient. The unit is safe, with integrated locking mechanisms to secure the table and instruments in place, thus protecting the patient.

Fully mobile for efficient examinations

Visionare Refraction Unit Portofino Visionare Refraction Unit Portofino Visionare Refraction Unit Portofino

The chair position can be adjusted. The physician can use the touchpad panel controls to raise and lower the chair. The chair can be manually reclined to a horizontal position, which is especially useful when applying drops during an examination. The chair can also be rotated 90 degrees, allowing the patient to easily enter and exit the seat.

Wheelchair Accessibility

For patients in wheelchairs or with mobility issues, the chair can be manually removed. The ophthalmic chair can be moved to the side using its own base plate, in order to make the unit accessible for wheelchair patients.

Visionare Refraction Unit Portofino – image 3

Chair Footrest and Armrests

The Portofino’s comfort features are not just for the doctor; this refraction unit is designed to keep the patient calm and secure throughout their entire visit. Comfortable armrests flank both sides of the ergonomic chair, while the footrest offers patients a convenient place to rest their feet and relax.

Visionare Refraction Unit Portofino Visionare Refraction Unit Portofino

Phoropter arm (sold separately)

The phoropter arm is adjustable and can be moved up and down. Once in the correct position, it is easy to lock it in place.

Visionare Refraction Unit Portofino – image 4

Illumination

The Portofino’s dimmable LED lighting system allows operators to easily adjust light intensity through the elegant electronic control panel, designed for intuitive operation. This superior lighting system provides specialists with the ideal environment for refraction and examination, enabling them to deliver clinical excellence while ensuring patient comfort.

Visionare Refraction Unit Portofino – image 5

Control Panel

The Portofino control panel does not solely serve to move elements. With the touchpad, the operator can easily activate the optotype projector and turn instruments on or off. Once an instrument is turned on, users can adjust the brightness level of the illumination from the panel. The controls also operate the included overhead light, which helps healthcare professionals see what they are doing regardless of ambient lighting.

Visionare Refraction Unit Portofino – image 6

Drawers

The refraction unit includes drawers for additional storage.

Visionare Refraction Unit Portofino – image 7

Safety

The Portofino is equipped with a variety of safety features. After rotating the table from one piece of equipment to the next, physicians or assistants can use the locking mechanism to keep the instrument in place. When ready to switch instruments again, simply unlock and return the table to the default position, or rotate it toward the next piece of equipment, reposition it in front of the patient, and lock it in place.

Careful design is the essence of the Portofino. This refraction unit can be ordered to be purchased and assembled for left-handed or right-handed operators. More importantly, the triple-arm table allows up to three different pieces of equipment to be used simultaneously.

Dimensions

Dimensions diagram
Visionare Refraction Unit Portofino – image 8

Visionare Refraction Unit Portofino videos

Video: How to Use - Portofino Refraction Unit
Video: General Description - Visionare
Video: General Description - Visionare Refraction Units

Specifications

Visionare Refraction Unit Portofino specifications
Dimensions without trial lens drawer Width: 71" Depth: 68"
Dimensions with trial lens drawer* Width: 71" Depth: 70mm
Input Voltage/Frequency 220-240 V~ 50/60 Hz
Input current 220-240 V~ max 1.4 A
2 main fuses located in the fuse holder at the rear of the column base Version 220-240 V~: T3.15A250V
Seat elevation power Max 330 lbs
Output voltage supply for instruments According to the version type. Available version types: 6 V and 6 V, 6 V and 12 V, 12 V and 6 V, 12 V and 12 V
Maximum power supplied by the instrument output 50 VA
Instrument light intensity controlled via touch panel Overhead lamp light intensity controlled via touch panel Chin rest mounting bracket included