Huvitz Autorefractor / Keratometer HRK-9000A

REQUEST QUOTEor call toll-free (888) 881-1122Financing available — simple terms, no leasing. Ask about it in your quote request.

The Huvitz HRK-9000A Autorefractor Keratometer provides objective measurement of refractive error and prescription for eyeglasses or contact lenses. Continuous efforts toward greater precision lead to objective refraction followed by standardized subjective refraction with the HRK-9000A, ultimately delivering unprecedented precision results. The HRK-9000A speaks not of compromises, but of perfectionism in refraction, encompassing glare testing, superior contrast sensitivity, and TFBUT / Meibography, introduced for the first time in the world. A beautiful curvilinear design conveys emotional stability. With the HRK-9000A, experience a level of satisfaction you have never known before.

Huvitz Autorefractor / Keratometer HRK-9000A

High-Precision Refractometry and Keratometry

Objective, fast, and reliable measurements for refraction and corneal curvature, providing precise data for a more comprehensive visual evaluation.

Advanced Visual Quality Testing

Includes subjective visual acuity testing, contrast sensitivity, and glare assessment, helping evaluate visual performance under different conditions.

Dry Eye Evaluation with TFBUT and Meibography

Enables analysis of the tear film stability and observation of the Meibomian glands, supporting a more comprehensive evaluation of dry eye.

Smart and Connected Workflow

7" color touchscreen, automatic tracking, auto-cut printer, and Wi-Fi connectivity for faster patient care.

Huvitz Autorefractor / Keratometer HRK-9000A – image 15
Huvitz Autorefractor / Keratometer HRK-9000A – image 16
Huvitz Autorefractor / Keratometer HRK-9000A – image 17
Huvitz Autorefractor / Keratometer HRK-9000A – image 18
Huvitz Autorefractor / Keratometer HRK-9000A – image 19
Huvitz Autorefractor / Keratometer HRK-9000A – image 20
Huvitz Autorefractor / Keratometer HRK-9000A – image 21
Huvitz Autorefractor / Keratometer HRK-9000A – image 22
Huvitz Autorefractor / Keratometer HRK-9000A – image 23
Huvitz Autorefractor / Keratometer HRK-9000A – image 24
Huvitz Autorefractor / Keratometer HRK-9000A – image 25
Huvitz Autorefractor / Keratometer HRK-9000A – image 26
Huvitz Autorefractor / Keratometer HRK-9000A – image 27
Huvitz Autorefractor / Keratometer HRK-9000A – image 28
Huvitz Autorefractor / Keratometer HRK-9000A – image 29
Huvitz Autorefractor / Keratometer HRK-9000A – image 30
Huvitz Autorefractor / Keratometer HRK-9000A – image 31
Huvitz Autorefractor / Keratometer HRK-9000A – image 32
Huvitz Autorefractor / Keratometer HRK-9000A – image 33

Subjective VA Test

The comparison between subjective and objective visual acuity (VA) tests generates more reliable and precise data. The subjective VA test is useful for determining the need for progressive lenses, as it verifies visual acuity based on patient responses.

Huvitz Autorefractor / Keratometer HRK-9000A – image 1

Contrast Sensitivity and Glare Test

Highly reliable nocturnal visual acuity can be assessed with the low contrast sensitivity test and the glare test, which perfectly reproduces the halo effect. Post-operative progress following refractive or cataract surgeries can be effectively monitored.

Huvitz Autorefractor / Keratometer HRK-9000A – image 2

TFBUT Measurement and Meibography

Tear film conditions and dry eye can be assessed through TFBUT (Tear Film Break-Up Time), providing a detailed understanding of visual acuity. Meibomian gland degeneration can also be monitored with an appropriate light source and an image enhancement function.

Huvitz Autorefractor / Keratometer HRK-9000A – image 3

Zernike Topographic Map Support

The Huvitz wavefront analysis algorithm goes beyond general refraction to determine with high precision and reliability the power and refractive index of the cornea. The wavefront technology measures the wavefront of light reflected by the retina and the refractive power with various sectoral sensors, analyzing them with extreme precision.

Huvitz Autorefractor / Keratometer HRK-9000A – image 4

Microlens Array

The Microlens Array developed by Huvitz creates several separate focal points, whose pattern provides valuable information about patients’ ocular system.

Huvitz Autorefractor / Keratometer HRK-9000A – image 5

More Accurate Data

KER data accuracy is improved by defining the ideal zone diameter at the measurement point; and REF data accuracy is enhanced by standardizing the fogging chart light quantity, the fogging lens position, and complete accommodation blocking.

Huvitz Autorefractor / Keratometer HRK-9000A – image 6

Color Display Mode

The color CCD camera and white LED light source of the autorefractor/keratometer allow visualization of the eyes and contact lens fitting, something that was previously only possible with slit lamps.

Huvitz Autorefractor / Keratometer HRK-9000A – image 7

Peripheral Keratometry Measurement

Continuous measurement at the corneal periphery, 90˚ vertically and horizontally from the center, provides curvature and eccentricity values for all points and allows optimal contact lens fitting.

IOL Mode

Additional measurement mode available for IOL power or visual acuity after cataract surgery.

Huvitz Autorefractor / Keratometer HRK-9000A – image 8

Iris and Pupil Diameter Measurement

The image capture function enables a highly precise examination by measuring iris and pupil diameters, with a range of 2 mm to 14 mm.

Huvitz Autorefractor / Keratometer HRK-9000A – image 9

Contact Lens Fitting Assistance Guide

The world’s first function for contact lens fitting in an autorefractor/keratometer allows fluorescein visualization under blue illumination.

Efficient Contact Lens Prescription

Image capture and contrast adjustment are available. The HRK-9000A offers the best On-K fitting guide based on base curve and KER value.

Huvitz Autorefractor / Keratometer HRK-9000A – image 10

7″ Color Tilting Touch Screen

The wide color TFT LCD display offers high-resolution images and real-time processing for quality free of afterimage. Furthermore, the rotating and tilting touch screen can be read from any direction, facilitating communication between examiners and patients.

Huvitz Autorefractor / Keratometer HRK-9000A – image 11

Automatic Tracking

State-of-the-art sensors and a three-dimensional movement mechanism automatically track the measurement focus of the eye and complete the measurement with precision, even with inexperienced users.

Huvitz Autorefractor / Keratometer HRK-9000A – image 12

Automatic Cutter Printer

The built-in printer allows printing 10 sets of measurement data in up to 3 seconds, noise-free. Paper roll replacement is performed with a single touch.

Huvitz Autorefractor / Keratometer HRK-9000A – image 13

Wireless Communication
System Connectivity

Wi-Fi wireless communication enables seamless data transfer with the HDR-9000 and HLM-9000, regardless of the working environment. Classic RS-232 cable communication is also available for data transmission with earlier models.

Huvitz Autorefractor / Keratometer HRK-9000A – image 14

Specifications

Huvitz Autorefractor / Keratometer HRK-9000A specifications
Measurement Mode
K/R Mode Continuous Keratometry and Refractometry
REF Mode Refractometry
KER Mode Keratometry
KER P Mode Peripheral Keratometry
Color Display Mode Color Visualization and Contact Lens Fitting Assistance (White and Blue LED Light)
Meibography Mode Special mode for Meibomian gland observation
TFBUT Mode Special mode for measuring TFBUT (Tear Film Break-Up Time)
Refractometry
Vertex Distance (VD) 0.0, 12.0, 13.5, 13.75, 15.0
Sphere (SPH) -30.00 ~ +25.00 (VD = 0.5 in / 12 mm) (Steps: 0.01, 0.12, 0.25 D)
Cylinder (CYL) 0.00 ~ 12.00 D (Increments: 0.01, 0.12 and 0.25 D)
Cylinder Format Plus and Minus (Mixed)
Pupillary Distance (PD) 0.4 ~ 3.35 in (10 ~ 85 mm)
Minimum Pupil Diameter ø 0.08 in / 2.0 mm
Keratometry
Radius of Curvature 0.2 ~ 0.5 in (5 ~ 13.0 mm) (Increments: 0.01 mm)
Corneal Power 25.96 ~ 67.50 D (increments: 0.05, 0.12, 0.25 D) (when the equivalent refractive index of the cornea is 1.3375)
Corneal Astigmatism 0.00 ~ -15.00 D (Increments: 0.05 / 0.12 / 0.25 D)
Axis 1 ~ 180° (Increments: 1°)
Pupil/Iris Diameter 0.08 ~ 0.55 in (2.0 ~ 14.0 mm) (Increments: 0.1 mm)
Data Memory 10 measurements per eye
Movement Range
Up and Down ±0.6 in / 15 mm
Left-Right ±0.2 in / 5 mm 0.08 in / ±2 mm
Up and Down ±0.6 in / 15 mm
Front-Back ±0.2 in / 5 mm 0.08 in / ±2 mm
Other
Display Wide 7-inch Color TFT LCD Display, touch panel with tilt function
Interface RS-232 x 1, USB (for service) x 1, Wi-Fi (for data communication)
Wi-Fi Band: 2.4 GHz, IEEE 802.11b/g Security: WPA2-PSK
Internal Printer Thermal line printer with automatic cutting function
Energy Saving Auto Power Off (5 min)
Power Supply 100-240VAC, 1.0-0.6A, 50/60Hz
Dimensions / Weight 10.3(W) X 20.4(D) X 17.4(H) in / 41.8 lb (262(W) X 518(D) X 441(H) mm / 19 kg)
Visual Acuity Test — Subjective Refractive Test
Visual Acuity Measurement 0.1/0.1/0.25/0.32/0.4/0.5/0.63/0.8/1.0/1.25 | 20/200 / 20/200 / 20/80 / 20/60 / 20/50 / 20/40 / 20/30 / 20/25 / 20/20 / 20/16
Sphere (SPH) -22 D to +22 D (0.25 D steps)
Cylinder (CYL) 0 to ±10 D (max., 0.25 D increment)
Cyl (Axis) 0 to 180˚ (1˚/5˚ increment)

Manuals & Catalogs

Catalogs

Huvitz Autorefractor / Keratometer HRK-9000A

Huvitz Autorefractor / Keratometer HRK-9000A – catalog cover
Manuals

Huvitz Autorefractor / Keratometer HRK-9000A

Huvitz Autorefractor / Keratometer HRK-9000A – manual cover