EZ-OTO-1800 ION - US Ophthalmic
EZ-OTO-1800 ION - US Ophthalmic
EZ-OTO-1800 ION - US Ophthalmic
EZ-OTO-1800 ION - US Ophthalmic
EZ-OTO-1800 ION - US Ophthalmic
EZ-OTO-1800 ION - US Ophthalmic
EZ-OTO-1800 ION - US Ophthalmic
EZ-OTO-1800 ION - US Ophthalmic
Load image into Gallery viewer, EZ-OTO-1800 ION - US Ophthalmic
Load image into Gallery viewer, EZ-OTO-1800 ION - US Ophthalmic
Load image into Gallery viewer, EZ-OTO-1800 ION - US Ophthalmic
Load image into Gallery viewer, EZ-OTO-1800 ION - US Ophthalmic
Load image into Gallery viewer, EZ-OTO-1800 ION - US Ophthalmic
Load image into Gallery viewer, EZ-OTO-1800 ION - US Ophthalmic
Load image into Gallery viewer, EZ-OTO-1800 ION - US Ophthalmic
Load image into Gallery viewer, EZ-OTO-1800 ION - US Ophthalmic

$600.00 $620.00


$600.00


Hurry, only 5 item(s) left in stock!
10 visitors are looking this product!

ophthalmoscope and otoscope diagnostic set ez-oto-1800 ion ezer - us ophthalmic
The Ezer OPH-1800 ION Ophthalmoscope has been designed with comfort and functionality in mind, and provides powerful performance to help you examine the eyes of patients. The 2.5v, 1.6w bulb provides stunning clarity that’s suitable for non-dilated, small-pupil diagnostics, and the Ezer OPH-1800 ION comes with 19 different lenses, ranging from 0D to ±20D.

ophthalmoscope and otoscope diagnostic set ez-oto-1800 ion ezer - us ophthalmic
Also included in this diagnostic set is the Ezer OTO-1800 ION Otoscope, a powerful ear-examination device that’s been crafted with ease of use and operation in mind. The Ezer Otoscope uses fiber optics to provide more light output at the tip of the device while reducing harmful glare, and provides up to 2.5x magnification. The device also comes with a full set of reusable ear specula, measuring 2.5mm and 4mm. The powerful, focused light and fantastic magnification of this Otoscope make it a perfect choice for your ear diagnostic needs, and it provides fantastic views of the tympanic membrane and external ear canal.

ophthalmoscope and otoscope diagnostic set ez-oto-1800 ion ezer - us ophthalmic
Also included with the kit is a hard-sided zippered carrying case, and a charging dock that can recharge the internal batteries of both devices simultaneously, making the Ezer Ez-OTO-1800 ION Ophthalmoscope and Otoscope Diagnostic set perfect for the physician on the go!
Ophthalmoscope
Optical Specifications
19 Various lenses ranging in power from 0D to ±20D 0D, ±1D, ±2D, ±3D, ±4D, ±6D, ±8D, ±10D, ±15D, ±20D
Aperture Red-free filter
Large spot
Small spot
Hemispot
Fixation aperture
Electrical Specification
Rated Voltage Two AA alkaline or Ni-MH batteries
Type of bulb 2.5 V / 1.6 W
Electrical Safety Standard Complying with EN60601-1 / EN60601-1-2
Protection: Internal electrical power source
Operation mode: Intermittent. 2 minutes 'ON'. 5 minutes 'OFF'
Environment Requirements
Operation Environment Temperature
Relative Humidity
Atmospheric Pressure
+10 °C - +35 °C
30% - 75%
700 hPa - 1060 hPa
Shipping Common Conveyance  
Storage Temperature
Rel. humidity
Air Pressure
-40 °C - +55 °C
10% - 90%
500 hPa - 1060 hPa

Otoscope
Optical Specifications
Illumination Fiber optics transmit light
Magnification of lens 2.5 x
Specifications of ear-specula
Diameter of ear-specula 0.10in/2.5mm, 4mm
Specifications of insufflation Port
Insufflation Port Yes
Electrical Specification
Bulb T4954 2.5V / 0.16in/1.6W
Rated Voltage Two AA alkaline or Ni-MH batteries
Operation Mode Intermittent: on time should not exceed 2 min with off-time not less than 5 min
Electrical Safety Complying with EN60601-1 / EN60601-1-2
Protection: Internal electrical power source
Type BF applied part
Environment Requirements
Operation Environment Temperature
Relative Humidity
Atmospheric Pressure
+10 °C - +35 °C
30% - 75%
700 hPa - 1060 hPa
Shipping Common Conveyance  
Storage Temperature
Re. Humidity
Air Pressure
-40 °C - +55 °C
10% - 90%
500 hPa - 1060 hPa

Charger
Electrical Specifications
Input Voltage 5VDC
Input Power 3VA + 15%
Lithium Battery Specifications 3.7V
Charging Port 2
Maximum Charge Time <=3.5h
Electrical Safety Complying with EN60601-1 / EN60601-1-2
Protection: Class II IPX0
Insufflation Port Yes
Power Adapter Specification
Type UE15WCPP1-050200SPA
Input 100 VAC - 240 VAC
50 Hz / 60 Hz
Input Power <=15 VA
Output 5 VDC / 2 A
Electrical Safety Complying with EN60601-1 / EN60601-1-2
Protection: Class II IP20
Environment Requirements
Operation Environment Temperature
Relative Humidity
Atmospheric Pressure
+10 °C - +35 °C
30% - 75%
700 hPa - 1060 hPa
Shipping Common Conveyance  
Storage Temperature
Re. Humidity
Air Pressure
-40 °C - +55 °C
10% - 90%
500 hPa - 1060 hPa
Ophthalmoscope
Optical Specifications
19 Various lenses ranging in power from 0D to ±20D 0D, ±1D, ±2D, ±3D, ±4D, ±6D, ±8D, ±10D, ±15D, ±20D
Aperture Red-free filter
Large spot
Small spot
Hemispot
Fixation aperture
Electrical Specification
Rated Voltage Two AA alkaline or Ni-MH batteries
Type of bulb 2.5 V / 1.6 W
Electrical Safety Standard Complying with EN60601-1 / EN60601-1-2
Protection: Internal electrical power source
Operation mode: Intermittent. 2 minutes 'ON'. 5 minutes 'OFF'
Environment Requirements
Operation Environment Temperature
Relative Humidity
Atmospheric Pressure
+10 °C - +35 °C
30% - 75%
700 hPa - 1060 hPa
Shipping Common Conveyance  
Storage Temperature
Rel. humidity
Air Pressure
-40 °C - +55 °C
10% - 90%
500 hPa - 1060 hPa

Otoscope
Optical Specifications
Illumination Fiber optics transmit light
Magnification of lens 2.5 x
Specifications of ear-specula
Diameter of ear-specula 0.10in/2.5mm, 4mm
Specifications of insufflation Port
Insufflation Port Yes
Electrical Specification
Bulb T4954 2.5V / 0.16in/1.6W
Rated Voltage Two AA alkaline or Ni-MH batteries
Operation Mode Intermittent: on time should not exceed 2 min with off-time not less than 5 min
Electrical Safety Complying with EN60601-1 / EN60601-1-2
Protection: Internal electrical power source
Type BF applied part
Environment Requirements
Operation Environment Temperature
Relative Humidity
Atmospheric Pressure
+10 °C - +35 °C
30% - 75%
700 hPa - 1060 hPa
Shipping Common Conveyance  
Storage Temperature
Re. Humidity
Air Pressure
-40 °C - +55 °C
10% - 90%
500 hPa - 1060 hPa

Charger
Electrical Specifications
Input Voltage 5VDC
Input Power 3VA + 15%
Lithium Battery Specifications 3.7V
Charging Port 2
Maximum Charge Time <=3.5h
Electrical Safety Complying with EN60601-1 / EN60601-1-2
Protection: Class II IPX0
Insufflation Port Yes
Power Adapter Specification
Type UE15WCPP1-050200SPA
Input 100 VAC - 240 VAC
50 Hz / 60 Hz
Input Power <=15 VA
Output 5 VDC / 2 A
Electrical Safety Complying with EN60601-1 / EN60601-1-2
Protection: Class II IP20
Environment Requirements
Operation Environment Temperature
Relative Humidity
Atmospheric Pressure
+10 °C - +35 °C
30% - 75%
700 hPa - 1060 hPa
Shipping Common Conveyance  
Storage Temperature
Re. Humidity
Air Pressure
-40 °C - +55 °C
10% - 90%
500 hPa - 1060 hPa

Recently viewed