autorefractor 2win adaptica - us ophthalmic
Applications and Benefits of the 2WIN

The 2Win finds diverse applications across various fields, including ophthalmic and optometric practices, pediatric eye care, orthoptics, pediatricians' offices, vision screening programs, mobile eye care services, and occupational medicine. Its versatility and portability make it an ideal tool for conducting objective assessments and screenings in both clinical settings and remote environments, ensuring efficient and accurate eye examinations across different patient demographics and healthcare scenarios.

autorefractor 2win adaptica - us ophthalmic

Practice applications of the 2Win include rapid patient vision testing and screening, refraction and vision analysis for infants (0-3 years old), vision care for disabled or uncooperative patients, analysis of binocular vision and accommodative balance, early detection and documentation of various amblyogenic factors, objective analysis of under- or over-corrections, and objective orthoptic exams. This device facilitates comprehensive and precise assessments across different patient populations, ensuring efficient diagnosis and treatment planning in clinical and non-traditional healthcare settings alike.

autorefractor 2win adaptica - us ophthalmic
Eccentric Photo-Retinoscopy

The 2WIN measurement principle is eccentric photo-retinoscopy. Infrared (IR) light is projected through the patient’s pupils and onto the retina. Depending upon the refractive error, the reflected light forms a specific crescent-shaped brightness pattern within the pupil.

autorefractor 2win adaptica - us ophthalmic

The 2WIN measures spherical power, cylinder power, and axis by interpreting the reflected light crescent pattern and position. The 2WIN infrared exam also provides valuable information about corneal abnormalities as well as ocular media opacities such as cataracts.

autorefractor 2win adaptica - us ophthalmic
Binocular / Monocular Refraction in a light controlled environment

When used with the Kaleidos module, the 2WIN can be used in a light controlled environment, eliminating distractions while fixing the distance for measurement. In this pairing, the instrument can be used for rapid walk-up screenings in any light conditions.

autorefractor 2win adaptica - us ophthalmic
Extended Measurement Range

The 2WIN covers an impressive measurement range of spherical power from -15D to +15D.

autorefractor 2win adaptica - us ophthalmic
Phorias and Tropias Early Detection

The 2WIN is capable of diagnosing myopia, hyperopia, astigmatism, and others. Additionally, it will provide evidence of sight anomalies that may be related to anisometropia, anisocoria, phorias, or strabismus.

autorefractor 2win adaptica - us ophthalmic
Pupil Size Measurement

The 2WIN provides accurate and instant pupil size, pupil distance, and head tilt measurements.

autorefractor 2win adaptica - us ophthalmic
Gaze Measurement

This package will add the feature to collect data from three measurements and will analyze the corneal reflex. The results will be expressed either in prism diopters or in degree.

autorefractor 2win adaptica - us ophthalmic
Fully Automated and Easy to Use

The 2WIN works as a camera and operates at three feet (1 meter) distance. It needs only 3 seconds to get a complete screening of the patient. It then immediately provides a detailed PDF report to print and share.

autorefractor 2win adaptica - us ophthalmic
Screening Report

With the 2Win, the customer can complete an objective assessment of the visual function in natural vision conditions. It is ideal for infants, children, the handicapped, and non-cooperative patients, due to the 2WIN’s small footprint and reduced exam time.

autorefractor 2win adaptica - us ophthalmic
Connect to IR Printer

2WIN measurements can be printed and stored internally on a micro-SD card using a PDF format, which is capable of storing 1,000+ results.

autorefractor 2win adaptica - us ophthalmic
WIFI

The 2WIN’s built-in WiFi connects seamlessly to the internet, making it possible to share results and diagnostics via email. The 2WIN also utilizes its WiFi capability to connect directly to the VisionFit.

autorefractor 2win adaptica - us ophthalmic
Refract patients of all ages

The 2WIN can be used for patients as young as two months old and up to 120 years old.

 

2WIN Videos


English Version

Spanish Version

Portuguese Version

Click here to see the brochure

Click here to see the brochure
Operating Mode Binocular / Monocular
Refraction Measurement Automatic
Sphere Range +15, -15 D, step 0.25 D
Cylinder Range +5, -5 D, step 0.25 D
Cylinder Axis 1° – 180°, step 1°
Pupil Size Automatic Detection, 0.15-0.27in (4-7 mm), step 0.004in (0.1 mm)
Pupil Distance Automatic Detection, 1.18-4.72in (30-120 mm), step 0.04in (1 mm)
Fixation Target Built-in
Acoustic Target 1 m ± 5 cm
Data Interface Wi-Fi, USB, microSD card
Printer Interface USB, Infrared (irda)
Power Rechargeable Battery
Battery Charger 110-220 Vac, 0.5 A
Size 6.5 x 5.11 x 3.9 in (165 x 130 x 98 mm)
Display 3.5’’
Weight 1.85 lb (0.83 kg)
Options / Accessories Portable wireless printer, supplementary battery, battery-charger, metal case, Wi-Fi connectivity