Ft999.191


Hurry, only 1 item(s) left in stock!
10 visitors are looking this product!

slit lamp esl-7800 ezer - us ophthalmic

Advanced Optic System
The optics in the ESL-7800 Slit Lamp are ideal for technologically advanced imaging systems. An optical beamsplitter featuring an "in-out" prism system allows maximum illumination to the practitioner during observation and likewise enables to digital and video imaging systems when these tools are in position. The dual port beamsplitter also allows an assistantscope to be attached.

slit lamp esl-7800 ezer - us ophthalmic

Magnification Selection Dial
Operators can select from five steps of magnification simply by twisting a single knob. Changing an eyepiece is not required. Using the conveniently located knob, operators can select from total magnification ratios equivalent to 6x (Ø33mm), 10x (Ø22.5mm), 16x (Ø14mm), 25x (Ø8.8mm), 40 (Ø5.5mm).

slit lamp esl-7800 ezer - us ophthalmic

Large Binocular Field of View with Wide Range of PD and Diopter Adjustment
Ezer's ESL-7800 Galilean converging optical system offers a very large binocular field of view of Ø33mm, Ø22.5mm, Ø14mm, Ø8.8mm, and Ø5.5mm, with a 55mm-75mm range of PD adjustment and -5D to +3D diopter adjustment.

slit lamp esl-7800 ezer - us ophthalmic


Two Fixation Targets
The ESL-7800 offers two options with respect to fixation targets. One is for diopter adjustment to help the patient to see the target clearly while the other is an illuminated fixed spot. The fixation target with diopter compensation supplies a dot and concentric circles target. Operators simply slide the knob to adjust the diopter compensation within the range from -15D to +10D. The fixation target with spot light is especially well suited to patients with refractive errors exceeding -15D.

slit lamp esl-7800 ezer - us ophthalmic
Continuous Slit Rotation and Aperture Adjustment
The ESL-7800 features 2/3x slit projection magnification and enables users to modify slit width continuously from 0mm to 9mm. The slit becomes a circle at 9mm. A helpful scale on the knob indicates the width value. The slit height also can be changed continuously, from 1mm to 8mm. Aperture diameters are Ø9mm, Ø8mm, Ø5mm, Ø3mm, Ø2mm, Ø1mm, and Ø0.2mm. The slit angle is continuously adjustable from vertical to horizontal from 0° to 180°. Four steps of slit inclination—5°, 10°, 15°, 20° — also are available for oblique illumination in contact lens evaluations.

slit lamp esl-7800 ezer - us ophthalmic

Ergonomicaly Designed Illumination Control
The smooth classic design of the ESL-7800 allows for precise movements and easy operation of the joystick and knobs. For example, the illumination lever is conveniently located next to the joystick. The brightness control switch can be set to High or Normal, making diagnostic procedures even easier.

slit lamp esl-7800 ezer - us ophthalmic

Accessories Mount
This ESL-7800 slit lamp can be equipped with the TN-150 / TN-150B applanation tonometer as well as several other accessories.

slit lamp esl-7800 ezer - us ophthalmic

Fundus Observation
Unlike standard slit lamp units, Ezer's ESL-7800 also allows for a dilated examination of the fundus and the posterior segment of the vitreous body using a Hruby Lens with the unit's Hruby Lens Holder and Hruby Lens Guide Plate.

slit lamp esl-7800 ezer - us ophthalmic

High Clarity Luminance and Built-in Filters
The ESL-7800 utilizes a bulb that provides incredible clarity. Four built-in Illumination Pathway Filters can be effortlessly inserted into the illumination pathway using the selection lever. Options include a heat absorption filter that aids in patient comfort during lengthy exams, a red-free filter that enhances structural contrast, a cobalt blue filter for use in fluorescein assessment, and a grey filter.

slit lamp esl-7800 ezer - us ophthalmic

Integrated Control Joystick
The integrated Joystick is simple to control and allows operators to acquire sharp images. The base operation of the ESL-7800 offers the following movements to provide flexibility, comfort and precision—forward and back movement to 90mm; left and right movement to 100mm, fine movement to15mm and vertical movement to 30mm. The joystick moves horizontal for fine-tuning and vertical for height and target alignment. Once you achieve the proper alignment, the base can be locked to prevent sliding.
Microscope
Type Galileo magnification changer with converging
Model Magnifying 5 steps by drum rotation
Eyepiece 12.5x
Total Magnification Rate
6x 10x 16x 25x 40x
(Field of view) (ø 1.3in / 33mm) (ø 0.9in / 22.5mm) (ø 0.6in / 14mm) (ø 0.31in / 8mm) (ø 0.2in / 5.5mm)
Range of P.D. Adjustment 2.16 to 3 in (55 to 75 mm)
Diopter Adjustment -5D to +3D
Illumination
Slit Projection Magnification 2/3x
Slit Width continuous from 0mm to 0.35in / 9mm
(at 0.35in / 9mm, slit becomes a circle)
Slit Height continuous from 0.04in / 1mm to 0.31in / 8mm
Aperture Diameter ø0.35in, ø0.31in, ø0.2in, ø0.12in, ø0.08in, ø0.04in, ø0.008in (ø9mm,ø8mm,ø5mm,ø3mm,ø2mm,ø1mm,ø0.2mm)
Slit Angle 0º to 180º continuously adjustable from vertical to horizontal
Slit Inclination 5º, 10º, 15º, 20º four steps
Filter Piece heat-absorption, Gray, Red-free and Blue
Illumination Bulb 6V20W halogen bulb
Movement Base
Fore and Back Movement 3.54in / 90mm
Left and Right Movement 4in / 100mm
Fine Movement 0.6in / 15mm
Vertical Movement 1.2in / 30mm
Chin-rest Parts
Vertical Movement 3.14in / 80mm
Fixation Target Red-LED
Hurby Lens
Hurby Lens -58.7D (optionally available in some regions)
Power Source
Input Voltage 100/220V ~ ±10%
Input Frequency 50/60 Hz
Input Power 30VA
Output Voltage Illumination bulb 0V ~ 6V
Fixation target 6V
Electric Safe Standard Conform to Standard IEC601 - 1, Class I Type B
Dimension and Weight
Packing Box 28.34 x 19.5 x 19in (720 x 495 x 480mm)
Total Weight 52.8lb / 24Kg
Net Weight 46.2lb / 21 Kg
Microscope
Type Galileo magnification changer with converging
Model Magnifying 5 steps by drum rotation
Eyepiece 12.5x
Total Magnification Rate
6x 10x 16x 25x 40x
(Field of view) (ø 1.3in / 33mm) (ø 0.9in / 22.5mm) (ø 0.6in / 14mm) (ø 0.31in / 8mm) (ø 0.2in / 5.5mm)
Range of P.D. Adjustment 2.16 to 3 in (55 to 75 mm)
Diopter Adjustment -5D to +3D
Illumination
Slit Projection Magnification 2/3x
Slit Width continuous from 0mm to 0.35in / 9mm
(at 0.35in / 9mm, slit becomes a circle)
Slit Height continuous from 0.04in / 1mm to 0.31in / 8mm
Aperture Diameter ø0.35in, ø0.31in, ø0.2in, ø0.12in, ø0.08in, ø0.04in, ø0.008in (ø9mm,ø8mm,ø5mm,ø3mm,ø2mm,ø1mm,ø0.2mm)
Slit Angle 0º to 180º continuously adjustable from vertical to horizontal
Slit Inclination 5º, 10º, 15º, 20º four steps
Filter Piece heat-absorption, Gray, Red-free and Blue
Illumination Bulb 6V20W halogen bulb
Movement Base
Fore and Back Movement 3.54in / 90mm
Left and Right Movement 4in / 100mm
Fine Movement 0.6in / 15mm
Vertical Movement 1.2in / 30mm
Chin-rest Parts
Vertical Movement 3.14in / 80mm
Fixation Target Red-LED
Hurby Lens
Hurby Lens -58.7D (optionally available in some regions)
Power Source
Input Voltage 100/220V ~ ±10%
Input Frequency 50/60 Hz
Input Power 30VA
Output Voltage Illumination bulb 0V ~ 6V
Fixation target 6V
Electric Safe Standard Conform to Standard IEC601 - 1, Class I Type B
Dimension and Weight
Packing Box 28.34 x 19.5 x 19in (720 x 495 x 480mm)
Total Weight 52.8lb / 24Kg
Net Weight 46.2lb / 21 Kg