High Speed
Provides High-speed Scan (68,000 A-scan/sec.), High-quality Image by using Huvitz’s outstanding optical technology and innovative image software. Shows extensive information, such as 3D structure of Retina, Macula's thickness and separation, in a vivid image.

Accurate and Stable Image Averaging
It is very important to obtain high-quality images that are accurate and stable in all OCTs. However, it’s not easy to capture these due to patient eye movement over the period of the test. The HOCT detects fast eye movements with image processing algorithms of fast Scan Speed* and Smart Viewing Technology(SVT)** and scans up to 68,000 points per second, and calibrates to create a high-quality optical image. HOCT can acquire high-quality images without any repetitive operation for first time users.

*68,000 A-scan / sec., Less than 1.4 sec. in 6x6 mm2 3D shooting
** Smart Viewing Technology : Huvitz’s Speckle-Noise-Reduction System & Pre-Acquiring Algorithm to acquire high-quality images


optical coherence tomography hoct-1 huvitz - us ophthalmic
Vividly Visualized Retinal Layers
Visualizing with precise B scans and smooth 3D images at faster scan speeds makes it easier to observe pathological shapes and status in stratified Retinal Layers. It is also useful to further elucidate the pathological rheobase of Macula and Optic Disc, including factors that impair Photoreceptor Function, Retinal & Choroidal Vasculature(vascular system) in a slice image for Retinal Layer consists of 7 pieces.

optical coherence tomography hoct-1 huvitz - us ophthalmic
Brightness Level Adjustment
Precisely identify lesions by minutely adjusting image's brightness and contrast. In this way, specific parts of lesions can be highlighted which help users to easily see details.

optical coherence tomography hoct-1 huvitz - us ophthalmic

Combined-One
By combining OCT, and PC, it can generate high resolution images providing multi-purpose functions for diagnosis. It saves both time and space by performing frontal view(Enface) of eye diseases, Tomography, cross-compare and diagnosis in a single run.
Provides maximum psychological stability to the patient without re-shooting and reduces stress during shooting*. 

*Motion detection technology:Smart Scan Technology (SST) is applied to achieve perfect images without re-shooting even though there’re flicker or movement (see Smart Scan page).



Compact Design
Thanks to HOCT's space-saving design its perfect for hospitals and research areas with many diagnosis devices and treatment equipment, It can maximize the convenience of users as well as patients, thus saving time and space.


optical coherence tomography hoct-1 huvitz - us ophthalmic
Web Browsing System
Patient's test data can be analyzed anywhere on the Internet. You can check and analyze all data of HOCT through Web Browser such as Internet Explorer, Safari, Chrome without installing special software separately.


optical coherence tomography hoct-1 huvitz - us ophthalmic

optical coherence tomography hoct-1 huvitz - us ophthalmic

optical coherence tomography hoct-1 huvitz - us ophthalmic
Fast and Stable Full Auto Mode
Simply press the button once to capture the image quickly and easily without any errors with Auto Tracking, Optimize, Auto Shooting at the correct position. Depending on the application, select Semi Auto to obtain more detailed images.

Semi Auto Mode
You can obtain a more precise image by shooting Semi Auto Mode turning one’s gaze to the side for patients with eye diseases such as cataract, strabismus, or optic disk and peripheral measurements. Semi Auto Mode can also be applied to eyes with weak signals. XY alignment, focus is automatically adjusted, and manual operation during auto adjustment is also possible. Focusing and Firing functions can be judged and involved by users so that users can obtain images in an intuitive way.


Wide Area Scan(12mm x 9mm)
A quick scan covers Macula and Optic Disk areas extensively. By scanning around Optic Disc or Macula for patient's pathological status, you can check the Thickness Maps between RNFL(Retinal Nerve Fiber Layer), GCL(Ganglion Cell Layer) and RPE Layers.

Smart Scan Technology with Motion Detection Technology
Image analyzer with Huvitz's unique Smart Scan Technology(SST) obtains a complete and perfect C-scan image by detecting any motion of eye flicker or movement that would prevent disappearance of scan line and image collection during measurement.


Providing Various and Useful Scan Patterns
12 different patterns make it available to choose and apply the optimized pattern to the main symptoms or the area of retinal disease without repetitive work or time-wasting.


Compare before and after patient's symptom
You can compare and analyze the baseline data of a patient with the current data.


3D Modeling in High Speed and Wide Area
High-speed, wide area(12mm x 9mm) 3D images help you quickly and comprehensively understand the condition of the Retina. Also, layer thickness maps can be used from ILM to RPE, respectively and Morphological changes on the measured surface of the layers can also be visually confirmed.


OU to Cross-Analyze Function of Binocular
Provides comparative analysis for Macular Thickness, RNFL Thickness, ONH(Optic Nerve Head) of binocular.


Detailed Report
Provides patient's pathological structure and relevant & important data in easy-to-read format and also can print out the report on analysis screen. Analysis results can be viewed via Web Browser and printed out with different types of reports.

optical coherence tomography hoct-1 huvitz - us ophthalmic optical coherence tomography hoct-1 huvitz - us ophthalmic

optical coherence tomography hoct-1 huvitz - us ophthalmic

9mm Wide Chamber View
Measurement of ACA(Anterior Chamber Angle) between cornea and Iris allows diagnosis and management of angle-closure glaucoma patients.

9mm High Resolution Cornea Thickness Measurement
The 9mm high-resolution Cornea Scan provides an objective view of the structure of the eyeball and displays a cross-sectional image of the measured corneal thickness.


optical coherence tomography hoct-1 huvitz - us ophthalmic

Corneal Thickness Map
Corneal's irregularity, Thinnest point, etc. can be identified with a corneal thickness map to visualize the patient's corneal thickness at a glande.


High Resolution and Performance 12 Megapixel Camera
High performance camera with Motion Artifact Suppression Technique provides high resolution images and also its low intensity of flash, fast & quiet operation maximize measurement quality.


Auto-Detection Of Pupil Size and Auto Flash Level Function
It accurately measures the pupil size and automatically adjusts the intensity of light according to pupil size. Even patients with small pupil size can be easily measured without switching mode. Selecting Small Pupil Mode, to be adjusted more intensive light for the small pupil size.


Fixation Target for Flexible Configuration
Fixation target can be set on the display for fine adjustment of a specific part of the eyeball.

Angiography (Optional Module)
By One-Button, accurate details are provided with high-resolution images for vessels of retina & choroid and data of FAZ, flows, density.

The function provides high-resolution images for vessels of retina & choroid with quantified index. It can be utilized with early diagnosis & treatment progression for macular degeneration, diabetic retinopathy, glaucoma, hypertensive retinopathy and retinal vein occlusion. Also, users can check abnormal vasculature in Custom View.

Since the analysis shows index for FAZ, Flows, Density, it's easy to establish treatment plan.





* Detail Display for Accurate Index and Evaluation
In Detail Mode, users can specifically observe vascular network per layer.
Using analyzing tool, details of FAZ can be acquired conveniently.



* Retina Layer Auto-Analysis
The function provides high-resolution images for vessels of retina & choroid with quantified index. It can be utilized with early diagnosis & treatment progression for macular degeneration, diabetic retinopathy, glaucoma, hypertensive retinopathy and retinal vein occlusion.
Also, users can check abnormal vasculature in Custom View.
Since the analysis shows index for FAZ, Flows, Density, it's easy to establish treatment plan.



* Detail Display for Accurate Index and Evaluation
In Detail Mode, users can specifically observe vascular network per layer.
Using analyzing tool, details of FAZ can be acquired conveniently.



* Progression
The Progression mode helps users to follow up the pathology of a disease.
Binocular Comparison (OU)



* In the Comparison Mode, users can check vascular network by layer in detail.
By indicating layers in different colors, it's easy to check and understand the pathology of a disease. In case of comparison for diabetic retinopathy, the mode helps to track the pathology and establish treatment plan.




* A Variety of Scan Sizes
3 mm / 4.5 mm / 6 mm / 9 mm
HOCT-Angiography supports a variety of scan sizes, users can choose and observe per needs & cases.



* Angio Panorama
In case of checking Angiography image with large size, it is convenient to utilize the Angio Panorama function.
*3 mm (Max. 12 mm x 9mm), 4.5 mm (Max. 13.5 mm x 9 mm) & manual mode are available


Topography (Optional Module)
Comprehensive Analysis by Topography in OCT Method : Providing Total Cornea Power Map able to measure Anterior & Posterior.
Total Cornea Power Map
Since the HOCT can analyze the posterior of the cornea, Users can now minimize errors caused by anterior & posterior axis of the cornea, corneal thickness, and refractive errors caused by the vitreous and corneal structures.





Compact Layout with Various Options
With 16 Map types, Users can analyze Sim-K, Meridian, and Keratoconus data

* Analysis Display / Numerical Information
Users can analyze with either Single Eye, OU, or Comparison functionality. It is also possible to check for clinical changes after treatment or surgery with the Progression function.







Because the Map displays accurate distance, size, and area with numerical information, the User is able to perform their analysis with confidence.
Sim-K: Typical curve in order to utilize optimal IOL Lens calculation
Meridian: Provide ø3, 5, 7 mm meridian by dividing the cornea into 3 areas
Pachymetry: Total Thickness of Cornea
Epithelium: Provide epithelium thickness at each point


16 Map Types for Customized Treatment
HOCT provides 16 map types including the anterior & posterior surfaces of the cornea. Users can display a wide variety of options to analyze and diagnose. In particular, posterior corneal surface measurements that allow for more accurate surgical outcomes.accuracy than the Placido or Scheimpflug methods. It minimizes motion artifacts because of its 2-second high speed capture rate.







16 Map Types for Customized Treatment
HOCT provides 16 map types including the anterior & posterior surfaces of the cornea. Users can display a wide variety of options to analyze and diagnose. In particular, posterior corneal surface measurements that allow for more accurate surgical outcomes.
Biometry (Optional Module)
HOCT provides all the data you need for quick and easy calculations for optimizing the IOL lens power.
Biometry from the Cornea to the Macula.
From the Cornea to the Macula, HOCT displays 2D images and provides all data along the anterior and posterior segments.
After measurement is complete, the User can identify and make adjustments where necessary. Also, it is possible to evaluate a dense cataract or defects in the macula.





Visible Measurement by 2D Image
User can easily adjust lines to analyze structures, by moving the cursor on the monitor in real-time. This can allow for a customized treatment of the non-typical Patient.




More Precise Biometry
Accurate Measurement by 2D Image:
Visualize & Measure in Full Anterior Image of 16 mm

* Confirmation Display able to Choose & Readjustment

Users can make adjustments along the axial line, as well as remove measurements that fall outside of normal in order to create accurate statistics for the IOL calculation.


* Full Anterior Image for Wider Evaluation
With the Wide Lens measurement, Users can obtain a full anterior image. With a simple click the CCT, ACD, ACA, W-to-W, LV, TISA, and TID* can be identified to aide in the diagnosis and management of Glaucoma.


* Contact Lens Fitting with Instant Check
HOCT allows Users to check the suitability of Hard & Soft Contact Lenses for their Patients. It can also check the fit of an existing Contact Lens, quickly & precisely.



* Reliable IOL Lens Recommendation
HOCT recommends the optimal IOL Lens Power, based on biometry & corneal curvature with clinical data so that Users can easily make their surgical plan taking into consideration dense cataracts, corneal disease, or glaucoma.




* View Function to Check the Basis of Disease
Full Anterior Image, 12 types of Cornea Tomograph, Biometry Data (AL, LT, CCT, ACD) Tomography Image of Cornea.
Comparison of asymmetry between left & right eyes with OU display.


OCT
Resolution(in Tissue) Z:6~7um, XY:20um
A Scan Rate 68,000 A-scan/sec.
Scan Range [Cornea] X,Y:6-9mm
3-D Acquisition Time 1.4s(Fastest mode, A512 x B96)
Min. Pupil Diameter Ø0.1in / 2.5mm
Light Source Wavelength SLD 840nm
Optical Power at Cornea ≤650uW
Scan Pattern Macular Line, Macular Cross, Macular Radial, Macular Raster, Macular 3D, Disc Circle, Disc Radial, Disc Raster, Disc 3D
Common
Working Distance 1.3in / 33mm
LCD Size 12.1", Resolution 1280x800
Dioptic Compensation Full Range:-33 to +33D
-33 to -7D with Minus Compensation Lens+7 to +33D with No Compensation Lens
Internal Fixation Lamp LCD
Horizontal Movement 70mm (back and forth) / 100mm (left and right)
Vertical Movement 1.18in / 30mm
Chinrest Movement 2.44in / 62mm, Motorized
Auto Alignment X,Y for Positioning, Z for Working Distance
Auto Focusing Diopter Adjustment for Focusing
Network DICOM File support (Need to be customized)
Normative Database Will be constructed after a release
Built in Computer O
Others
Power Supply AC100 ~ 240V, 50/60Hz, 1.6A~0.7A
Dimensions / Weight 13(W) x 21(D )x 20(H) in / 66lb (330(W) x 542(D )x 521(H) mm / 30kg)
Optional Accessories Anterior Segment Adapter, Web Viewer
Anterior Segment
Module(optional)
Scan Patterns: ACA Line, Cornea Radial, Cornea 3D
Software Analysis: Corneal Layers, Thickness Map, Thickness & Angle
Web Viewer(optional) Web-based, Multy users can be accesible
Progression Analysis, Comparion Analysis, 3D Analysis

HOCT-1 - Step by Step - Spanish Version

HOCT-1 - Step by Step - Portuguese Version



HOCT-1F - Introduction to the Modules - Spanish Version

HOCT-1F - Introduction to the Modules - Portuguese Version



HOCT-1F - Topography Module - Spanish Version

HOCT-1F - Topography Module - Portuguese Version

HOCT-1F - Topography Module - English Version



HOCT-1F - Angiography Module - Spanish Version

HOCT-1F - Angiography Module - Portuguese Version



HOCT-1F - Biometry Module - Spanish Version

HOCT-1F - Biometry Module - Portuguese Version



HOCT-1F - Commercial Presentation - Spanish Version

HOCT-1F - Commercial Presentation - Portuguese Version



HOCT-1F - Commercial Presentation - Spanish Version

HOCT-1F - Commercial Presentation - Portuguese Version



HOCT-1F - Commercial Presentation - Spanish Version

HOCT-1F - Commercial Presentation - Portuguese Version

Recently viewed