Skip to content
Search
+1 (888) 881-1122 REQUEST QUOTE

Clinical Areas:

Retina and Fundus

Glaucoma and Intraocular Pressure

Myopia Control

Cataract

Ezer EFC-2600 Retinal Camera

REQUEST QUOTEor call toll-free (888) 881-1122Financing available — simple terms, no leasing. Ask about it in your quote request.

The EFC-2600 is a fully automated, entry-level non-mydriatic retinal camera with an advanced 3D tracking system capable of capturing high-definition retinal images in any eye care practice. The camera quickly delivers consistent color fundus images using multiple imaging modalities. The 45° FOV images help streamline the detection of retinal abnormalities and the early diagnosis of diabetic retinopathy, glaucoma, macular degeneration, and other growing conditions. As an easy-to-operate device, any eye care center can use the EFC-2600 to make a diagnosis without the need for a specialist. If an abnormality is detected, the telemedicine feature on the EFC-2600 is ideal for quickly obtaining the opinion of remote specialists.

Ezer EFC-2600 Retinal Camera
Ezer EFC-2600 Retinal Camera – image 14
Ezer EFC-2600 Retinal Camera – image 15
Ezer EFC-2600 Retinal Camera – image 16
Ezer EFC-2600 Retinal Camera – image 17
Ezer EFC-2600 Retinal Camera – image 18
Ezer EFC-2600 Retinal Camera – image 19
Ezer EFC-2600 Retinal Camera – image 20
Ezer EFC-2600 Retinal Camera – image 21
Ezer EFC-2600 Retinal Camera – image 22
Ezer EFC-2600 Retinal Camera – image 23
Ezer EFC-2600 Retinal Camera – image 24
Ezer EFC-2600 Retinal Camera – image 25
Ezer EFC-2600 Retinal Camera – image 26
Ezer EFC-2600 Retinal Camera – image 27
Ezer EFC-2600 Retinal Camera – image 28
Ezer EFC-2600 Retinal Camera – image 29
Ezer EFC-2600 Retinal Camera – image 30
Ezer EFC-2600 Retinal Camera – image 31
Ezer EFC-2600 Retinal Camera – image 32
Ezer EFC-2600 Retinal Camera – image 33
Ezer EFC-2600 Retinal Camera – image 34
Ezer EFC-2600 Retinal Camera – image 35
Ezer EFC-2600 Retinal Camera – image 36
Ezer EFC-2600 Retinal Camera – image 37
Ezer EFC-2600 Retinal Camera – image 38
Ezer EFC-2600 Retinal Camera – image 39
Ezer EFC-2600 Retinal Camera – image 40
Ezer EFC-2600 Retinal Camera – image 41
Ezer EFC-2600 Retinal Camera – image 42
Ezer EFC-2600 Retinal Camera – image 43
Ezer EFC-2600 Retinal Camera
Ezer EFC-2600 Retinal Camera – image 45
Ezer EFC-2600 Retinal Camera – image 46
Ezer EFC-2600 Retinal Camera – image 47
Ezer EFC-2600 Retinal Camera – image 48
Ezer EFC-2600 Retinal Camera – image 49
Ezer EFC-2600 Retinal Camera – image 50
Ezer EFC-2600 Retinal Camera – image 51
Ezer EFC-2600 Retinal Camera – image 52
Ezer EFC-2600 Retinal Camera – image 53
Ezer EFC-2600 Retinal Camera – image 54
Ezer EFC-2600 Retinal Camera – image 55
Ezer EFC-2600 Retinal Camera – image 56
Ezer EFC-2600 Retinal Camera – image 57
Ezer EFC-2600 Retinal Camera – image 58
Ezer EFC-2600 Retinal Camera – image 59
Ezer EFC-2600 Retinal Camera – image 60
Ezer EFC-2600 Retinal Camera – image 61
Ezer EFC-2600 Retinal Camera – image 62
Ezer EFC-2600 Retinal Camera – image 63
Ezer EFC-2600 Retinal Camera – image 64

Using the EFC-2600

The imaging process does not depend on the user, resulting in high-quality images regardless of the operator’s experience level. The fully automated focus and capture functions allow anyone to easily perform the examination and obtain the highest quality photos. The ease of image capture also enables a relaxed and pleasant experience for the patient.

Ezer EFC-2600 Retinal Camera – image 1

Live previews of the eye are visible on the touchscreen. The operator initiates image capture with a single press of a button on the touchscreen, and the software instructs the patient to focus on the green light while image capture is performed. The entire process is efficient and can take as little as 30 seconds per eye. The non-intrusive nature of the EFC-2600 makes the entire image capture process fast and effortless for the patient, promoting high patient compliance.

Ezer EFC-2600 Retinal Camera – image 2

Mosaic Function — Enhanced Image Visualization and Diagnosis

Retinal diseases affect both the center and the periphery of the retina. By providing an enhanced view of the retina, mosaic imaging has revolutionized the diagnosis of retinal diseases. With ten selectable fixation targets, the mosaic modality of the EFC-260 allows the operator to capture high-quality images of all points of interest in the retina up to 85 degrees.

The automatic mosaic function combines multiple retinal fields without user intervention to create a seamless panoramic image of the selected fixation targets. These digital montages can be displayed on a large screen to facilitate the diagnosis of retinal pathologies.

Ezer EFC-2600 Retinal Camera – image 3

A Side-by-Side Comparison allows you to compare different patient images from different dates.

Ezer EFC-2600 Retinal Camera Ezer EFC-2600 Retinal Camera

Easy Image Visualization and Diagnosis

The 12-megapixel high-resolution camera and red-free digital images enhance the visualization of retinal vasculature, enabling rapid diagnosis and detailed documentation of retinal changes associated with disease progression. In addition to the red-free mode, it features a complementary function that allows you to view the red-free image in different grayscale levels. The features, image quality, and analysis provided by the EFC-2600 drive our current eye care toward a future of high-quality, affordable healthcare for everyone.

Ezer EFC-2600 Retinal Camera Ezer EFC-2600 Retinal Camera Ezer EFC-2600 Retinal Camera

RGB filters aid in the diagnostic process by enhancing the visibility of ocular alterations. Red light is useful for imaging choroidal melanomas, choroidal nevi, pigmentary changes, choroidal ruptures, and inflammatory lesions. Green light provides fine contrast and the best fundus view for observing normal and pathological retinal vascularization, hemorrhages, and exudates. Blue light overcomes the barriers of white light to improve visibility of the anterior retinal layers and provide detailed images of the retinal nerve fiber layer, internal limiting membrane, retinal folds, epiretinal membranes, and cysts. The camera also features a negative film mode that enhances image contrast when light intensity is brighter.

Ezer EFC-2600 Retinal Camera Ezer EFC-2600 Retinal Camera

The retinal imaging capabilities of the EFC-2600 enhance precision and efficiency in the early detection and accurate diagnosis of retinopathies.
The ease of use and installation of the EFC-2600 allows any primary eye care center to operate and provide early detection of retinopathies, reducing disparities among patient populations by improving access to screening examinations.

Ezer EFC-2600 Retinal Camera – image 4

The EFC-2600 is also equipped to capture high-quality images of the anterior segment, facilitating imaging of the cornea, iris, ciliary body, and lens, enabling early detection of anterior segment disorders.

Ezer EFC-2600 Retinal Camera – image 5

Easy operation and pleasant patient experience
During the examination, the patient is instructed to rest their chin on the chinrest and their forehead against the headband. At this stage, the operator simply adjusts the motorized chinrest to the patient’s height through the intuitive interface using the 10.1-inch color touchscreen. The application interface allows the operator to select which eye to examine and choose from ten different internal fixation targets to capture more fixation targets than other retinal cameras currently available. Disc, fovea, macula, or other peripheral image capture is easily enabled in this way.

Ezer EFC-2600 Retinal Camera – image 6
Ezer EFC-2600 Retinal Camera Ezer EFC-2600 Retinal Camera

Early and rapid detection of diabetic retinopathy and other retinal diseases. Diabetic retinopathy (DR) is the leading cause of permanent visual impairment in adults. When left untreated, DR can lead to serious vision problems, including vitreous hemorrhage, retinal detachment, glaucoma, and ultimately, blindness.

Ezer EFC-2600 Retinal Camera – image 7

This debilitating disease affects approximately 30% of adults over 40 years of age with diabetes and is even more prevalent in underrepresented racial, ethnic, and socioeconomic groups that do not have easy access to screening examinations. Despite DR being so prevalent, patients may not experience symptoms in the early stages, making early detection of DR critical. Low detection rates result in late referrals to specialists and vision loss.

Ezer EFC-2600 Retinal Camera – image 8

Adaptability

The EFC-2600 features an adaptable interface and is easy to install in any eye care center. Seamless image transfer is possible as the EFC-2600 is compatible with Digital Imaging Communications in Medicine (DICOM) and easily integrates with other patient software.

Ezer EFC-2600 Retinal Camera – image 9

Desktop Viewer

Patient data can be transferred to the Desktop Viewer to be analyzed and stored on a separate Windows PC. All electronic patient files and reports can be stored on the device and shared with specialists via the cloud or email.

Ezer EFC-2600 Retinal Camera Ezer EFC-2600 Retinal Camera

Expanding Access to High-Quality Healthcare Through Telemedicine

The EFC-2600 is much more than a simple camera — it can generate dynamic reports. All electronic patient files and reports can be stored on the device and shared with specialists via the cloud or email. It features output ports such as USB, which allow the export of patient images, and HDMI, which enable patient images to be displayed on a larger screen. These networking capabilities allow the device to support telemedicine services, providing expert opinions on all captured images. The telemedicine function delivers reliable patient data protection and improves access to exceptional-quality healthcare. Specialists can review images and prepare medical reports around the clock. This support reduces costs for patients associated with general practitioner visits and unnecessary hospitalizations.

Ezer EFC-2600 Retinal Camera

Ezer EFC-2600 Retinal Camera – image 10

Ezer EFC-2600 Retinal Camera

Artificial Intelligence (AI)

To assist in the diagnostic process, the EFC-2600 can implement detection using artificial intelligence (AI). The EFC-2600 can be integrated with any AI software. Recent advances in technology have trained AI to detect vision-threatening diseases with a high degree of accuracy.

Ezer EFC-2600 Retinal Camera – image 11

As modern practices generate an overwhelming volume of images, AI-assisted detection is the future of efficient and objective ophthalmology. AI detection with the EFC-2600 simplifies diagnosis and maximizes efficiency in every practice.

Ezer EFC-2600 Retinal Camera – image 12
Ezer EFC-2600 Retinal Camera – image 13

Ezer EFC-2600 Retinal Camera videos

Video: Eye Doctors - Retinal Camera EFC-2600 Ezer
Video: Primary Care - Retinal Camera EFC-2600 Ezer
Video: Oveview - Retinal Camera EFC-2600 Ezer

Specifications

Ezer EFC-2600 Retinal Camera specifications
Type Non-mydriatic digital retinal camera
Photography type Color, digital red-free, anterior segment image
Image format JPEG, PNG, DICOM (optional)
Field of View 45 degrees
Minimum pupil size 4.0 mm
Working distance 25 mm
Focus adjustment range -15D to +10D (w/o compensation lens) -30D to -10D or +5D to +30D (with compensation lens)
Flash Intensity 10 levels, can be set manually
Light source Observation light source: infrared LED Flash light source: white LED
Auto Exposure Yes
Image 12 MP
Eye fixation Ten internal points
Alignment Fully automatic 3D tracking
Chin rest movement Motorized
Networking capability Yes
Interface USB 2.0, Ethernet, HDMI
Power supply AC 100V to 240V, 50/60Hz, auto selected
Operating Environment Temperature: 10℃ to 35℃ Humidity: 30% to 90% (non-condensing)
Dimensions (W x D x H) 282 mm x 485 mm x 492 mm
Weight 38 pounds

Manuals & Catalogs