Skip to content
Search
+1 (888) 881-1122 REQUEST QUOTE

Clinical Areas:

Retina and Fundus

Glaucoma and Intraocular Pressure

Myopia Control

Cataract

Huvitz Vision Screener HVS-1

REQUEST QUOTEor call toll-free (888) 881-1122Financing available — simple terms, no leasing. Ask about it in your quote request.

The HVS-1 is designed to rapidly and accurately evaluate individuals of all ages, from infants as young as six months to adults, including those with limited mobility who may have difficulty with traditional desktop autorefractors. This advanced device detects refractive errors in less than one second from a distance of 1 meter, making it an essential tool for identifying amblyopia risk factors such as myopia, hyperopia, astigmatism, and strabismus.

Although particularly beneficial for young children, where early detection is critical, the HVS-1 is equally effective for adults, offering unparalleled versatility and precision. Its patented Focus LED technology enhances accuracy through increased light intensity, ensuring reliable results.

Discover the convenience and precision of the HVS-1 Vision Screener by Huvitz, designed to meet the needs of patients of all ages.

Huvitz Portable Autorefractor HVS-1

Fast and Efficient Visual Assessment

Performs visual assessments in just a few seconds, enabling quick and practical identification of potential vision problems.

Portable and Lightweight Design

Compact and easy to transport equipment, ideal for use in clinics, schools, outreach campaigns, and mobile care settings.

Simple Operation with Instant Results

Intuitive interface that facilitates use and delivers immediate results, with no need for complex procedures.

Ideal for Large-Scale Visual Evaluation Programs

Perfect for visual health campaigns, allowing a large number of patients to be seen quickly and efficiently.

Huvitz Portable Autorefractor HVS-1 – image 7
Huvitz Portable Autorefractor HVS-1 – image 8
Huvitz Portable Autorefractor HVS-1 – image 9
Huvitz Portable Autorefractor HVS-1 – image 10
Huvitz Portable Autorefractor HVS-1 – image 11
Huvitz Portable Autorefractor HVS-1
Huvitz Portable Autorefractor HVS-1 – image 13
Huvitz Portable Autorefractor HVS-1 – image 14
Huvitz Portable Autorefractor HVS-1 – image 15
Huvitz Portable Autorefractor HVS-1 – image 16
Huvitz Portable Autorefractor HVS-1 – image 17
Huvitz Portable Autorefractor HVS-1 – image 18
Huvitz Portable Autorefractor HVS-1 – image 19
Huvitz Portable Autorefractor HVS-1 – image 20
Huvitz Portable Autorefractor HVS-1 – image 21
Huvitz Portable Autorefractor HVS-1 – image 22
Huvitz Portable Autorefractor HVS-1 – image 23
Huvitz Portable Autorefractor HVS-1 – image 24
Huvitz Portable Autorefractor HVS-1 – image 25
Huvitz Portable Autorefractor HVS-1 – image 26
Huvitz Portable Autorefractor HVS-1 – image 27
Huvitz Portable Autorefractor HVS-1 – image 28

Contactless Measurement in a Single Step

The Portable Autorefractor HVS-1 offers contactless measurement in a single step, rapidly evaluating refractive anomalies such as myopia, astigmatism, hyperopia, and strabismus in less than one second from a distance of 1 meter, similar to taking a photo. This feature enables convenient measurement for infants who cannot sit independently, as they can be measured while being held by a caregiver, and for elderly individuals with mobility issues, who can be assessed comfortably without the need to move. Furthermore, its child-friendly measurement method captures the child’s attention with light and sound, encouraging them to focus on the center of the vision screener. In addition, integrated with a global camera sensor, the HVS-1 minimizes motion blur during the rapid measurement process, ensuring accurate results.

Huvitz Portable Autorefractor HVS-1 – image 1

Accurate Measurement with Focus LED Technology

The HVS-1 Portable Autorefractor ensures accurate measurement with its focus LED technology, precisely measuring eyes while minimizing the impact of external light. This patented technology features higher LED intensity, enabling detailed and precise measurements. For optimal accuracy, use in a dark environment is recommended. Furthermore, the HVS-1 offers enhanced measurement accuracy thanks to its high-resolution camera and advanced optometric measurement algorithms, powered by a quad-core CPU. These features provide more precise optometric data, ensuring reliable results for comprehensive eye examinations.

Huvitz Portable Autorefractor HVS-1 – image 2

Reliable Analysis Results

The HVS-1 Portable Autorefractor provides reliable analysis results by evaluating light reflection from the retina. Through this process, it precisely identifies refractive errors and ocular alignment anomalies, ensuring a reliable and comprehensive analysis for effective eye examinations.

Huvitz Portable Autorefractor HVS-1 – image 3

Easy connectivity with various devices

The HVS-1 Portable Autorefractor is equipped with a clear, wide-angle IPS monitor, ensuring a bright display and providing users with optimal visibility from any angle. This feature enhances usability during examinations, allowing for easy and accurate data interpretation. In addition, the HVS-1 offers seamless connectivity with a variety of devices. It not only supports the standard DICOM format for compatibility, but also allows users to conveniently review measured data on a PC using the HIIS-1 software (not included). This comprehensive connectivity ensures efficient data management and analysis, making the HVS-1 an invaluable tool in eye care settings.

Huvitz Portable Autorefractor HVS-1 – image 4

Detection report provision and convenient printing method

The HVS-1 Portable Autorefractor offers detection report provision and hassle-free printing functionality. With the optional Bluetooth printer, users can easily generate and print detection reports without the limitations of cables. This feature ensures efficient, wireless printing, enabling seamless distribution of results for analysis or patient record management.

Huvitz Portable Autorefractor HVS-1 – image 5

The HVS-1 Portable Autorefractor offers versatile data transmission methods and efficient search and management capabilities. With a database capacity of up to 7,000 individuals, users can quickly access and search data by page, enabling streamlined data retrieval. Furthermore, the HVS-1 supports bulk data transfer to a computer via multiple methods, including USB, cable, and WIFI. This ensures fast and convenient data transfer for further analysis or record-keeping, enhancing overall workflow efficiency.

Huvitz Portable Autorefractor HVS-1 – image 6

Huvitz Portable Autorefractor HVS-1 video

Video: Vision Screener HVS-1 Huvitz

Specifications

Huvitz Portable Autorefractor HVS-1 specifications
Sphere Range: -8.0D to +8.0D Increment step: 0.01D, 0.25D Accuracy: -3.50D to +3.50D / ± 0.5D -8.0D to < -3.50D / ± 1.0D > +3.50D to +8.0D / ± 1.0D
Cylindrical Range: -3.0D to +3.0D Increment step: 0.01D, 0.25D Accuracy: -1.50D to +1.50D / ± 0.5D -3.00D to < -1.50D / ± 1.0D > +1.50D to +3.00D / ± 1.0D
Axis Range: 0 - 180° Increment step: 1° Accuracy: ± 10°. For CYL values > 0.50D
Pupil size Range: 0.15 - 0.35 inch / 4.0 - 9.0mm Increment step: 0.004 inch / 0.1mm Accuracy: 0.016 inch / ± 0.4mm
Pupillary distance Range: 1.378 - 3.14 inch / 35 - 80mm Increment step: 0.04 inch / 1mm Accuracy: ± 0.06 inch / ± 1.5mm
Measurement time Average: ≤ 1s
Measurement distance Range: 39.4 inch ± 2 inch / 1000 mm ± 50 mm
LCD IPS 800x480
Printer BIXOLON Bluetooth thermal printer (optional)
Fixation target Visual pattern / audible sound
Wireless network 802.11 b/g/n
Interface USB 2.0

Manuals & Catalogs

Catalogs

Huvitz Portable Autorefractometer HVS-1

Huvitz Portable Autorefractometer HVS-1 – catalog cover
Manuals

Huvitz Portable Autorefractometer HVS-1

Huvitz Portable Autorefractometer HVS-1 – manual cover