Luxvision Applanation Tonometer TN-150B

REQUEST QUOTEor call toll-free (888) 881-1122Financing available — simple terms, no leasing. Ask about it in your quote request.

The Luxvision TN-150B Applanation Tonometer employs the most accurate clinical method for measuring IOP. The Luxvision TN-150B offers maximum flexibility and reliability. This Goldmann applanation tonometer can be used with either R-type or T-type mounts. Whether you are looking for a fixed unit or one that can be moved from room to room, the TN-150B can meet your needs. Widely recognized as the most common and straightforward method for assessing IOP, Goldmann applanation principle tonometers such as the TN-150B provide fast and efficient measurements.

Luxvision TN-150B Applanation Tonometer

World-standard Goldmann gold standard method

Uses the Goldmann applanation principle, globally recognized as the gold standard for IOP measurement since the 1950s. Provides the most accurate and direct clinical method available.

R or T mounting flexibility

Adapts to the changing needs of the practice with fixed mounting (R) or portable with guide plate (T) options. Allows the equipment to be used in a fixed location or transported between examination rooms.

Fast and efficient IOP measurements

Provides intraocular pressure assessments in an agile and reliable manner using the most widely used applanation method. Optimizes daily clinical workflow.

Versatile centering and observation system

Includes a notch position for precise prism centering with the left objective. Allows observation through the left or right eyepiece according to user preference.

Luxvision TN-150B Applanation Tonometer
Luxvision TN-150B Applanation Tonometer
Luxvision TN-150B Applanation Tonometer
Luxvision TN-150B Applanation Tonometer
Luxvision TN-150B Applanation Tonometer
Luxvision TN-150B Applanation Tonometer
Luxvision TN-150B Applanation Tonometer
Luxvision TN-150B Applanation Tonometer

The gold standard

Goldmann applanation tonometry is the most widely used tonometer in clinical practice and remains the “gold standard” for tonometry worldwide. It was developed in the 1950s and is based on the Imbert-Fick law, which states that the pressure within a liquid-filled sphere surrounded by an infinitely thin and flexible membrane is measured by the counter-pressure required to flatten said membrane into a plane.

Luxvision Applanation Tonometer TN-150B – image 1

Mounting Flexibility

The Luxvision TN-150B is a versatile unit that can adapt to the changing and growing needs of your practice. This high-quality tonometer offers precise measurements, whether with fixed R-type mounting or T-type mounting via a removable guide plate.

Luxvision Applanation Tonometer TN-150B – image 2

Versatility

A notched position ensures exact centering of the prism with the left objective. When using the guide plate, two positions can be selected, allowing the user to observe through the left or right eyepiece.

Luxvision Applanation Tonometer TN-150B – image 3

Specifications

Luxvision Applanation Tonometer TN-150B specifications
Measurement Range from 0 to 3.15inHg in increments of 0.079inHg (from 0 to 80mmHg in increments of 2mmHg)
Accuracy ± 0.02inHg / 0.5mmHg
Pneumatic Face Diameter 0.12in / 3.06mm
Measurement 1.85in/47mm Wide x 1.18in/30mm High
Weight 1.6lb / 725grams