Meridian Shortpulse Yellow Laser Photocoagulator Merilas 577
The Merilas 577nm yellow photocoagulators incorporate advanced short-pulse technology, enabling the tissue to cool down between laser pulses. This innovative feature minimizes or eliminates tissue damage, reducing the associated treatment risks and enhancing patient comfort and safety. With the Merilas 577, there is no occurrence of tissue damage or scarring.
Moreover, the Merilas 577 short-pulse ophthalmic yellow laser photocoagulator offers a dual treatment modality. It can be operated in subthreshold mode using microsecond pulses or continuous wave delivery mode, providing flexibility and versatility in treatment options.
SUPERIOR QUALITY & LONGEVITY
Meridian's unique solid feeling is achieved through the use of high-grade aluminum in the construction of the Merilas housing. The housing is sturdy and provides a durable structure. The control panel, which is removable, is equipped with a crystal interface that is resistant to damage, long-lasting, and easy to clean.
Meridian's unique solid feeling is achieved through the use of high-grade aluminum in the construction of the Merilas housing. The housing is sturdy and provides a durable structure. The control panel, which is removable, is equipped with a crystal interface that is resistant to damage, long-lasting, and easy to clean.
Experience an innovative cooling system with the Merilas 577 - the thermoelectric cooling (TEC) system. Gone are the days of ventilation slots, as this cutting-edge technology renders the unit hermetically sealed, guaranteeing a dust-free system. The result? Enhanced longevity of the laser, giving you the confidence of consistent and reliable performance over time.
USABILITY
The Merilas 577 lasers are designed to be user-friendly, featuring intuitive commands that are easy to use. The touch display, which is detachable, incorporates glass technology, offering flexibility and an enhanced ergonomic design. The user interface is designed with simplicity in mind, ensuring ease of operation.
The Merilas 577 lasers are designed to be user-friendly, featuring intuitive commands that are easy to use. The touch display, which is detachable, incorporates glass technology, offering flexibility and an enhanced ergonomic design. The user interface is designed with simplicity in mind, ensuring ease of operation.
With the thermoelectric cooling system implemented in the Merilas lasers, users can enjoy a quiet and disturbance-free experience as there are no disruptive noises or air turbulences associated with traditional cooling methods.
These lasers are presented in a modern and compact manner, leaving a strong impression on users. Additionally, they are designed for easy transportation, with each laser being accompanied by a robust and practical carry-on case, ensuring convenience and protection during travel.
SAFETY
Auto Key Connector: The Merilas lasers are equipped with an auto key connector feature that recognizes the original probes and accessories connected to the console. This ensures compatibility and prevents any potential issues arising from incompatible or non-certified components.
Auto Key Connector: The Merilas lasers are equipped with an auto key connector feature that recognizes the original probes and accessories connected to the console. This ensures compatibility and prevents any potential issues arising from incompatible or non-certified components.
■ Merilas laser delivers stable laser output
■ Each laser accessory is calibrated and measured independently
■ Safe in the cornea
■ Remote support access
FLEXIBILITY & COMFORT
At Meridian, we understand the unique needs of ophthalmologists and retina specialists, which is why our Merilas laser system is designed with flexibility and comfort in mind. Our slit lamp delivery systems are thoughtfully engineered to seamlessly work with a wide range of slit lamp brands, including both Haag-Streit and Zeiss styles. This compatibility allows you to integrate the Merilas laser system effortlessly into your existing setup, ensuring a smooth and efficient workflow. The versatility of the Merilas lasers goes beyond slit lamps. They are also fully compatible with laser indirect ophthalmoscopes and endoprobes, providing you with a wide array of treatment options. This adaptability empowers you to deliver personalized care, tailor-made to suit the unique needs of each patient.
LASER EXCELLENCE
■ Yearly maintenance service assures the optimal performance of your laser
The history of Meridian AG, now known as Meridian Medical Group, is intricately linked to the development of medical Nd:YAG lasers. A defining milestone was the creation of the Microruptor II, a groundbreaking innovation jointly developed by Meridian engineers and Dr. Frankhauser. This revolutionary laser system redefined numerous ophthalmology treatments, opening new possibilities for medical professionals worldwide. Our dedication to innovation remains unwavering, as our development engineers continuously pioneer new technologies, which are then patented to ensure their uniqueness. We have an unyielding commitment to excellence, integrating the finest Swiss and European laser components into our systems to guarantee the highest quality and long-term reliability. At Meridian, engineering and integration practices are based on tried-and-tested methods, ensuring that our laser systems deliver peak performance consistently. This dedication to perfection extends to our highly skilled and experienced staff, who are driven to provide the level of service and results that our esteemed customers deserve and have come to expect.
TIPS FOR YOUR LASER
■ Yearly maintenance service assures the optimal performance of your laser
■ Follow the safety advice of the manufacturer and your regulatory body
■ Follow the intended use described in the IFU
CLINICAL INDICATION
Photocoagulation:
Retinal photocoagulation, pan-retinal photocoagulation (PRP) and intravitreal endophotocoagulation of vascular and structural abnormalities of the retina and choroids, including:
Photocoagulation:
Retinal photocoagulation, pan-retinal photocoagulation (PRP) and intravitreal endophotocoagulation of vascular and structural abnormalities of the retina and choroids, including:
■ Proliferative and non-proliferative diabetic retinopathy
■ Choroidal neovascularization
■ Branch retinal vein occlusion
■ Age-related macular degeneration
■ Retinal tears and detachments
■ Retinopathy of prematurity
■ Macular edema
■ Lattice degeneration
■ Central retinal vein occlusion
Iridotomy:
■ Iridotomy in angle closure glaucoma
Trabeculoplasty:
■ Trabeculoplasty in open angle glaucoma
Why choose the Merilas 577 in conjuction with Haag-Streit slit lamp?
The Haag-Streit instruments provide precise and safe treatment capabilities, thanks to their internal beam path. These instruments do not have any external parts that could be misaligned, ensuring accurate and consistent performance. Additionally, the unique 'Clear View' user protection filter adds another layer of safety.
The Haag-Streit instruments provide precise and safe treatment capabilities, thanks to their internal beam path. These instruments do not have any external parts that could be misaligned, ensuring accurate and consistent performance. Additionally, the unique 'Clear View' user protection filter adds another layer of safety.
The laser is directly integrated into the illumination path of the slit lamp, eliminating any additional obstacles between the slit lamp front lens and the patient's eye. This direct linkage ensures unobstructed visibility and enhances safety during the treatment process.
WAVELENGTH BENEFITS – WHY 577 nm?
- The 577 nm yellow wavelength minimizes the occurrence of retinal burns, resulting in reduced scotoma formation.
- This wavelength provides physicians with improved control over the interaction between the laser beam and tissue during treatments.
- Yellow light is not absorbed by xanthophyll, making it particularly suitable for macular treatments.
- Additionally, the 577 nm wavelength produces less scattered light, allowing it to penetrate existing opacities more effectively and reach the tissue with greater precision.
THE PRINCIPLE OF SHORT-PULSE
The short-pulse treatment mode is characterized by a sequence of bursts comprising microsecond pulses. This treatment mode aims to spare the tissue and minimize scarring by delivering non-visible, subthreshold laser impacts. It effectively treats various retinal pathologies while avoiding ophthalmoscopically observable laser effects on the treated tissue. The short-pulse treatment is commonly utilized for subvisible threshold laser treatments targeting the macular and perimacular areas. Extensive studies on 577nm wavelengths have demonstrated the clinical efficacy of subvisible laser treatments without causing tissue damage.
AVAILABLE TREATMENTS:
-
For macula treatment:
Diabetic Macular Edema (DME) is a common complication of diabetes, affecting the macula due to fluid accumulation. This condition can cause vision loss and requires prompt intervention.
Central Serous Retinopathy (CSR) is characterized by fluid leakage in the macula, leading to blurred or distorted vision.
- For proliferative diabetic retinopathy, panretinal photocoagulation (PRP) and anti-VEG therapy are commonly used treatments.
- Retinal tears and detachments can be treated through a process called "soldering" or "welding," in which a laser is used to seal the retina back in place.
- Ablation treatments, such as laser peripheral iridotomy (LPI), can be used to treat various eye conditions, including narrow-angle glaucoma.
Diabetic Macular Edema (DME) is a common complication of diabetes, affecting the macula due to fluid accumulation. This condition can cause vision loss and requires prompt intervention.
Central Serous Retinopathy (CSR) is characterized by fluid leakage in the macula, leading to blurred or distorted vision.
ACCESSORIES
The standard accessories include a foot switch, transport case, and safety goggles. The optional accessories include slit lamp adapters, laser indirect ophthalmoscope, safety filters (passive and active), endoprobes, and an external fan.
The standard accessories include a foot switch, transport case, and safety goggles. The optional accessories include slit lamp adapters, laser indirect ophthalmoscope, safety filters (passive and active), endoprobes, and an external fan.
- Foot switch: The foot switch is used to turn the laser on and off. It allows the surgeon to operate the laser without using their hands, which can help improve accuracy and reduce the risk of accidental firing.
- Transport case: The transport case is used to store and transport the laser safely. It helps protect the device from damage during transportation and storage.
- Safety goggles: The safety goggles are worn by the surgeon and other personnel in the room to protect their eyes from the laser light. They help prevent eye damage and reduce the risk of accidental exposure to laser radiation.
- External fan (OPTIONAL ACCESSORY): The external fan is used to cool the laser device during operation. Lasers generate a lot of heat, and the external fan helps prevent the device from overheating and potentially malfunctioning.
SLIT LAMP ADAPTER (OPTIONAL ACCESSORY)
At Meridian, we take immense pride in our integration of lasers with the Haag-Streit BQ slit lamp, setting us apart as the exclusive laser company partnering with Haag-Streit. Our team has meticulously designed a specialized, high-quality filter that perfectly complements the Haag-Streit BQ slit lamp. This thoughtful engineering ensures an uninterrupted view and easy access to the slit lamp, utilizing 577 nm or 532 nm wavelengths with utmost precision. With Meridian's slit lamp adapter, your vision during procedures remains unobstructed, allowing you to deliver eye care with confidence and accuracy. The well-being of our users is paramount to us. Therefore, our Meridian filters are specifically crafted to provide unparalleled light transmission while prioritizing the protection of your eyes. We understand the importance of safety and comfort during treatments, and our filters are designed to ensure a secure and comfortable experience for both you and your patients.
UNIVERSAL DESIGNOur universal adapter is designed to seamlessly couple with almost any Haag-Streit slit lamp, whether it be an original model or a compatible alternative. This inclusive approach allows you to effortlessly integrate the Merilas laser system into your practice, regardless of the specific slit lamp model you prefer. Durability is at the heart of our design, and the robust material enclosing the fiber ensures the adapter's longevity. With the Merilas universal slit lamp adapter, you can trust in its resilience, knowing that it will withstand the demands of your daily practice.
DELIVERY SYSTEMS – LIO – FEATURES (OPTIONAL ACCESSORY)
The delivery system for the Merilas 577 laser platform is optimized for exceptional performance. The laser is delivered coaxially with the user's viewing axis, ensuring precise targeting and accuracy. The system features a standard LED module with a neutral LED cooler color that provides bright illumination while also extending battery life. The high-contrast optics and built-in filters further enhance the precision and effectiveness of the laser. Additionally, the system has an intelligent optical system that can automatically adjust the optics and mirrors for optimal performance. Finally, the delivery system comes with a high magnification lens that provides an additional 1.6x magnification for even greater precision and accuracy.
DELIVERY SYSTEMS – LIO – TECHNICAL SPECIFICATIONS
DELIVERY SYSTEMS – PROBES (OPTIONAL ACCESSORY)
Meridian's endoprobes are made by EMTRON with strict quality control to ensure high-quality polished fibre surfaces, resulting in even laser spots and eliminating the risk of "hot spots" during treatment. The endoprobes come with unique serial numbers, providing the highest level of traceability. They are CE-marked and sterilized individually for single use, ensuring optimal safety during procedures.
DELIVERY SYSTEMS – AVAILABLE PROBES
The available probes for our delivery systems feature a comfortable and ergonomic grip design, ensuring a precise and safe fibre guidance for unparalleled treatment accuracy. The balanced hand piece and standard SMA connector of the laser port enhance the user's flexibility and versatility during procedures.
Click here to see the brochure
Safety Classifications | Class 4 |
Wavelength | 577 nm |
Power Output | 50 – 2500 mW |
Pulse Duration |
CW (continuous wave, pulsed) 1 – 5000 ms |
Pulse Interval | 1 – 5000 ms |
SP-Mode Settings |
shortpulse (continuous wave, chopped) shortpulse duration: 0.01 - 9.5 ms shortpulse interval: 0.1 - 9.5 ms |
Cooling | TEC |
Aiming Beam | Diode 635 nm, (0-1 mW in 9 steps) |
Dimensions | 9.84" x 8.66" x 4.13" |
Total Weight | 15.4 lb |
Power Requirements | 100 – 240 V, 50/60 Hz, 2 A max. |
Plane
|
|
Safety Classifications | Class 4 |
Wavelength | 577 nm |
Power Output | 50 – 2500 mW |
Pulse Duration |
CW (continuous wave, pulsed) 1 – 5000 ms |
Pulse Interval | 1 – 5000 ms |
SP-Mode Settings |
shortpulse (continuous wave, chopped) shortpulse duration: 0.01 - 9.5 ms shortpulse interval: 0.1 - 9.5 ms |
Cooling | TEC |
Aiming Beam | Diode 635 nm, (0-1 mW in 9 steps) |
Dimensions | 9.84" x 8.66" x 4.13" |
Total Weight | 15.4 lb |
Power Requirements | 100 – 240 V, 50/60 Hz, 2 A max. |
Plane
|
|